21
Cooking is uneven within the oven
Oven shelves are incorrectly posi-
tioned.
Check that the recommended
temperatures and shelf positions are
being used.
Do not frequently open the door un-
less you are cooking things that need
to be turned. If you open the door
often, the interior temperature will be
lower and this may affect the results
of your cooking.
Oven light (if available) does not
operate.
Lamp has failed.
Electrical supply is disconnected or
switched off.
Replace lamp according to the
instructions.
Make sure the electrical supply is
switched on at the wall socket outlet.
The timer buttons cannot be pressed
properly.
There is foreign matter caught be-
tween the timer buttons.
Touch model: there is moisture on
the control panel.
The key lock function is set.
Remove the foreign matter and try
again. Remove the moisture and try
again. Check whether the key lock
function is set.
The oven fan (if available) is noisy.
Oven shelves are vibrating.
Check that the oven is level.
Check that the shelves and any bake
ware are not vibrating or in contact
with the oven back panel.
6.2 TRANSPORT
If you need to transport the product, use the original product packaging and carry it using its original case. Follow the
transport signs on the packaging. Tape all independent parts to the product to prevent damaging the product during
transport.
If you do not have the original packaging, prepare a carriage box so that the appliance, especially the external surfac-
es of the product, is protected against external threats.
SERVICING
Annual service by an authorised person is recommended, or if any of the following conditions are noticed; incomplete
ignition, appreciable yellow tipping, carbon deposition, lifting, floating, lighting back or objectionable odour. Contact
1300 MYILVE (694 583)
7. TECHNICAL SPECIFICATIONS
7.1 INJECTOR TABLE
Burner: ULPG
Artusi Semi-PR
Burner 1
Burner 2
Burner 3
Burner 4
Burner 5
Injector Size: mm
0.65
0.85
0.96
0.65
0.50
Test point pressure: kPa
2.75
Nominal GC: Mj/h
5.8
9.6
12
5.8
3.8
Burner: NG
Injector Size: mm
1.18
1.55
1.70
1.18
0.90
Test point pressure: kPa
1.00
Nominal GC: Mj/h
6.2
10.1
12.85
6.2
3.55