MIC-216
4
ZONE 1
ZONE 2
ZONE 3
O U T P U T L E VE L
-18
-15
-12
-9
-6
-3
0
+3
+6
+9
dB
ZONE 5
ZONE 4
ZONE 6
ALL C
ALL
POWER
CHIME
T ALK
MIC
MICROPHONE WITH ZONE CONTROL
MIC-216
2
3
1
4 5
6 7
ON
OFF
CHIME
VOL.
MASTER
VOL.
MIC
VOL.
CHIME
2 TONE
4 TONE
LINK
24V
500
m
A
POWER
8 9
10
11
12
13
14
2. General description.
4. Nomenclature and functions.
3. Features.
The microphone with individual zone selection offers an integrated sound system
for uses such as background music, calls and fire alarm.
4.1 Front panel/Back panel
When the Unit is in Use.
An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.
• Do not place heavy objects on the unit as this may
cause it to fall or break which may result in personal
injury and/or property damage. In addition, the object
itself may fall off and cause injury and/or damage.
• Make sure that the volume control is set to minimum
position before power is switched on.
• Loud noise produced at high volume when power is
switched on can impair hearing.
• Do not operate the unit for an extended period of time
with the sound distorting. This is an indication of a
malfunction, which in turn can cause heat to generate
and result in a fire.
• Contact your ArtSound dealer as to the cleaning. If
dust is allowed to accumulate in the unit over a long
period of time, a fire or damage to the unit may result.
• If dust accumulates on the power supply plug or in the
wall AC outlet, a fire may result. Clean it periodically.
In addition, insert the plug in the wall outlet securely.
• Switch off the power, and unplug the power supply
plug from the AC outlet for safety purposes when
cleaning or leaving the unit unused for 10 days or
more. Doing otherwise may cause a fire or electric
shock.
• Selective or general calling options up to 6 zones
• Several calling microphones with the option of putting
them in order of priority (max. 6)
• Bell/gong function(2/4-tone)
• MIC/Bel/Master volume control
• Volume indication LED
• 24V DC power supply
1. Microphone connection
(XLR)
2. Volume output LED
3. Zone selection
4. Talk key
5. All zones selection key
6. Power LED
7. Tone key
8. ON/OFF switch
9. 24V DC input
10. RS-485 connection (to am-
plifier or additional MIC)
11. Tone volume control
12. MIC volume control
13. Master volume control
14. 2/4-tone selection