background image

 

4. 

Connection 

 

Plug the UPS into a 2-pole, 3-wire grounded receptacle. Then connect one 
computer-related device into each of the power receptacles supplied on the 
back of the UPS

 

5. 

Turn On/Off 

 

To  turn  on  the  UPS  unit,  press  the  power  switch  lightly.    To  turn  off  the 

UPS unit, press the power switch again.  
 

6. 

DC Start 

 

This Series are equipped with DC Start.  To start the UPS when AC utility 

power is not available, simply press the power switch. 

 

7. 

Green Power Function 

 

This UPS is equipped with Green Power Function.  If no load connects to 

the  UPS, it  will  automatically  shut  down  in  2 minutes  for  energy  saving  while 
power failure. 

 

8. 

Free Download Software 

– Win Power 

Win Power is a brand new UPS monitoring software, which provides 
user-friendly interface to monitor and control your UPS. This unique 
software provides safely auto shutdown for multi-computer systems 
while power failure. With this software, users can monitor and control 
any UPS on the same LAN no matter how far from the UPS. 

Installation procedure: 

 

Go to the website: 

      

http://www.ups-software-download.com/winpower.htm

 

 

Choose the operation system you need and follow the instruction 

described on the website to download the software. 

 

When downloading all required files from the internet, enter the serial 

No: 511C1-01220-0100-478DF2A to install the software. 

When your computer restarts, the Win Power software will appear as a 
green plug icon located in the system tray, near the clock. 

Содержание ART 600VA

Страница 1: ...ART 600VA LINE INTERACTIVE UPS USER MANUAL ...

Страница 2: ...I CONTENTS 1 Introduction 1 2 Safety Caution 2 3 System description 4 4 Specification 5 5 Installation and operation 6 6 Battery 8 7 Trouble Shooting 9 ...

Страница 3: ...s function enables the UPS to be started up without AC power supplied Although it s a small UPS it s equipped with Smart RS 232 Communication Port to offer users more benefits The download software helps users monitor UPS inside status The main features of UPS are listed below Microprocessor control guarantees high reliability Equipped with Boost and Buck AVR Built in RS 232 Communication Port Fre...

Страница 4: ...ed items such as medical equipment life support equipment microwave ovens or vacuum cleaners to UPS To reduce the risk of overheating the UPS do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces Unplug the UPS prior to cleaning and do not use liquid or spray detergent Do not dispose ...

Страница 5: ...emals das Gerät Das Gerät darf aus Gründen der elektrischen Sicherheit nur von authorisicrtem Servicepersonal geöffnct Wcrdcn Bei der Installation is darauf zu achten das der Gesamtableitstrom der USV und der and der USV angeschlossenen Verbraucher den Maximalwert von 3 5mA nicht überschreiten VORSICHT Explosionsgetahr bei unsachgemäßen Austausch der Batterie Ersatz nur durch denselben order einem...

Страница 6: ... Panel 1 Power Switch 2 LED Indicators AC Mode Green lighting Battery Mode Green flashing Back Panel 1 Output receptacles 2 AC input with AC fuse 3 Modem Phoneline Surge Protection 4 Communication Port 5 Circuit Breaker 1 2 3 4 5 ...

Страница 7: ...LOAD 10 MINUTES AT HALF LOAD RECHARGE TIME 8 HOURS TO 90 AFTER COMPLETE DISCHARGE TRANSFER TIME TYPICAL LESS THAN 6MS INDICATOR AC MODE GREEN LIGHTING BACKUP MODE GREEN FLASHING AUDIBLE ALARM BACKUP MODE SOUNDING EVERY 10 SECONDS BATTERY LOW SOUNDING EVERY 1 SECOND OVERLOAD SOUNDING EVERY 0 5 SECONDS FAULT CONTINUOUS SOUNDING PROTECTION FULL PROTECTION DISCHARGE OVERCHARGE AND OVERLOAD PROTECTION ...

Страница 8: ...echarged prior to use Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 8 hours with no load no electrical devices such as computers monitors etc connected 3 Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit and is free from excessive dust corrosive fumes and conductive con...

Страница 9: ...ailure 8 Free Download Software Win Power Win Power is a brand new UPS monitoring software which provides user friendly interface to monitor and control your UPS This unique software provides safely auto shutdown for multi computer systems while power failure With this software users can monitor and control any UPS on the same LAN no matter how far from the UPS Installation procedure Go to the web...

Страница 10: ...s 2 The following precautions should be observed when working on batteries 1 A battery can present a risk of electrical shock and high short circuit current 2 Do not short the battery terminals 3 Do not charge in a gas tight container 4 Do not dispose of battery or batteries in a fire 5 Flush with water at once if contact is made with electrolyte acid Store The Battery gradually loses its capacity...

Страница 11: ...ply is normal Overload of the UPS Verify that the load matches the UPS capability specified in the specs When power failure back up time is shorten 1 Overload of the UPS 1 Remove some non critical load 2 Battery voltage is too low 2 Charge battery 8 hours or more 3 Battery defect due to high temperature operation environment or improper operation to battery 3 Replace with the same type of battery ...

Страница 12: ... Elektronik San Müm Tic Ltd Şti Adres İMES Sanayi Sitesi D Kapısı Karşısı Kuru Sk No 26 Y Dudullu İstanbul Tel 90 216 365 82 21 pbx Faks 90 216 420 97 70 Web www artronic com tr E posta artronic artronic com tr ...

Отзывы: