background image

 

 

© 2004 – 2021 ARTRAY Co., Ltd   

990SWIR-TEC-CL   

Camera Link

 

Setting Manual

 

 

11

 

Rev.1.07

 

 
 

 

5.5.8. 

Capture mode 

Table 5-15: Preview Mode 

 

 

 

Format 

 

-p 

 

 

 

Details 

1: r = Capture mode 
2: Delimiter   
3: -p = Preview 
4: Line feed code 

Response 

Normal: OK

 

Abnormal: NG

 

Note 

Configures capture as preview mode 

 

Table 5-16: Trigger Mode 

 

 

 

Format 

 

-t 

 

 

 

Details 

1: r = Capture mode 
2: Delimiter   
3: -t = Trigger 
4: Line feed code 

Response 

Normal: OK

 

Abnormal: NG

 

Note 

Configures capture as trigger mode 

 

 

 

 

 

6. 

Settings 

6.1. 

Preparation 

Before connecting camera to your PC, please install Camera Link frame grabber board, including driver 
and all the software necessary.   
In some cases, it is required to register the license of the product, please complete the registration 
before starting using the camera. 
After installing, please open device manager to check if the grabber board is recognized normally. 
If you use our recommendations listed in table 2-2, the device names should be recognized as follows: 

Table 6-1: Devices Recognized 

No. 

Device 

PIXCI®EB1 PCI Express Camera Link Video Capture Board for Win XP/Vista/7/8/10-64bit 

PIXCI® Camera Link Serial Port (COM3

1

1

: Will be differ depending on systems. 

Содержание ARTCAM-990SWIR-TEC-CL

Страница 1: ... 2004 2021 ARTRAY Co Ltd 990SWIR TEC CL Camera Link Setting Manual 1 Rev 1 07 ARTCAM 990SWIR TEC CL Camera Link Setting Manual rev 1 07 ...

Страница 2: ...ons 5 5 1 About the settings of the product 5 5 2 Communication Method 5 5 3 Command Format 5 5 4 List of Commands 6 5 5 Commands Details 7 5 5 1 Reset 7 5 5 2 Shutter 7 5 5 3 Gain 8 5 5 4 Temperature Control 8 5 5 5 Mirror 9 5 5 6 Camera Information 9 5 5 7 Peltier 10 5 5 8 Capture mode 11 6 Settings 11 6 1 Preparation 11 6 2 Connect to Camera 12 6 3 Example of Serial Communication Software Setti...

Страница 3: ...Measure Serial Communication Software e g Tera Term PC Any which can adopt items mentioned above Camera Camera Link Cable The connector joining to camera should be SDR AC Adapter Please use the AC adapter we offer All the settings in this manual are under the condition with following devices which we recommend While using other devices users could adapt settings correspondent to the devices Table ...

Страница 4: ...tified Grayscale 63 000MHz 3 2 Resolution The following table shows the maximum pixels of this camera Table 3 2 Resolution Model Horizontal Pixels Vertical Pixels ARTCAM 990SWIR TEC CL 1280 1024 4 Connector Pin Assignment The connector pin assignment is as follows Table 4 1 Connector Pin Assignment Pin No Signal Name Pin No Signal Name 1 GND 14 GND 2 X0 15 X0 3 X1 16 X1 4 X2 17 X2 5 XCK 18 XCK 6 X...

Страница 5: ...lease be sure to use half width characters of ASCII code Table 5 2 Command Format 1 2 3 4 5 6 Format cmd 〼 opt 〼 val CR or LF or CR LF Details 1 One letter which represents the main purpose of the command 2 One space blank as delimiter 3 Option correspondent with the main purpose The format is a letter going after a 4 One space blank as delimiter 5 Value setting enter the value if necessary Decima...

Страница 6: ...mands Function cmd opt val Description Reset x Reset camera Shutter i v O Shutter speed setting Gain g v O Gain setting Temperature Control t v Sensor Temperature readout C vf FPGA Temperature readout C Mirror m V O Vertical mirror enable disable H O Horizontal mirror enable disable Camera Information n c Show camera name v Show firmware version Peltier Control p y Peltier ON n Peltier OFF Capture...

Страница 7: ...a 1 2 Format x Details 1 x Reset 2 Line feed code Response Normal OK Abnormal NG Note Resets camera 5 5 2 Shutter Table 5 5 Shutter Speed Settings 1 2 3 4 5 6 Format i 〼 v 〼 val Details 1 i Shutter 2 Delimiter 3 v Option shutter speed settings 4 Delimiter 5 Value of shutter speed 6 Line feed code Response Normal OK Abnormal NG Note Sets the shutter speed To calculate the shutter speed please refer...

Страница 8: ...e Control Table 5 7 sensor Temperature Readout 1 2 3 4 Format t 〼 v Details 1 t Temperature control 2 Delimiter 3 v Option temperature readout 4 Line feed code Response Normal temperature Abnormal NG Note To show the estimated temperature of camera sensor The temperature shown here is merely a reference Table 5 8 FPGA Temperature Readout 1 2 3 4 Format t 〼 vf Details 1 t Temperature control 2 Deli...

Страница 9: ...e disable vertical mirror Table 5 10 Mirror horizontal 1 2 3 4 5 6 Format m 〼 H 〼 val Details 1 m Mirror 2 Delimiter 3 H Option Horizontal 4 Delimiter 5 0 disabled 1 enabled 6 Line feed code Response Normal OK Abnormal NG Note To enable disable horizontal mirror 5 5 6 Camera Information Table 5 11 Camera Name 1 2 3 4 Format n 〼 c Details 1 n Camera information 2 Delimiter 3 c Option Camera name 4 ...

Страница 10: ...onse Normal Version 202012041730 example Abnormal NG Note To show firmware version 5 5 7 Peltier Table 5 13 Peltier ON 1 2 3 4 Format p 〼 y Details 1 p Peltier 2 Delimiter 3 y Peltier ON 4 Line feed code Response Normal OK Abnormal NG Note To enable peltier Table 5 14 Peltier OFF 1 2 3 4 Format p 〼 n Details 1 p Peltier 2 Delimiter 3 n Peltier OFF 4 Line feed code Response Normal OK Abnormal NG No...

Страница 11: ...1 Preparation Before connecting camera to your PC please install Camera Link frame grabber board including driver and all the software necessary In some cases it is required to register the license of the product please complete the registration before starting using the camera After installing please open device manager to check if the grabber board is recognized normally If you use our recommend...

Страница 12: ...Sample of device manager 6 2 Connect to Camera Please connect camera to the Camera Link frame grabber board with Camera Link cable Before connect AC adapter to the camera please start up the serial communication software Command will be sent from the camera once it is connected to the power ...

Страница 13: ...adapter to the camera Figure 6 2 Icon of Tera Term After starting the software please choose the port correspondent with the name shown in device manager At the time this manual is made it is shown as COM3 Figure 6 3 To Choose Serial Port on Tera Term Please click Setup on menu bar then choose Serial Port for communication method settings Please refer to table 5 1 Communication Method for details ...

Страница 14: ...other operation but not necessary to be Table 6 2 Communication Protocol Item Settings New line Receive CR New line Transmit CR LF Local echo Check the box Figure 6 5 To Set up Terminal on Tera Term After connecting camera with power Tera Term will be initialized Once the initialization is finished you will see OK on the dialog box Then you can send command to control camera Please note that camer...

Страница 15: ...up the software you will see welcome message and license information If you have already registered please click OK directly If a warning or precaution concerning the license shows up you may not complete the registration In that case please register the license to continue Figure 6 8 Welcome message Please click PIXCI from XCAP menu then choose PIXCI Open Close to open the dialog box Please click...

Страница 16: ...play area First please set communication settings choose Configure to set Camera Link configuration bit tap and color Please refer to table 3 1 to confirm the Camera Link format Figure 6 10 Configure Settings Second please set the resolution Please refer to table 3 2 to confirm the resolution of each model Figure 6 11 Resolution Settings ...

Страница 17: ... of Camera Link in Timing Please refer to table 3 1 to confirm the Camera Link format Figure 6 12 Timing Settings The settings are finished now The image will be displayed either by clicking Live in Capture on the sub window or simply by clicking Live Icon on the left side of the sub window Figure 6 13 Live Icon ...

Отзывы: