- 9 -
5. Connect the Camera
5-1
How to connect a camera
5-2
Shutter Speed
Shutter speed can be changed on the standard viewer software ART-Viewer.
The shutter speed is set directly on the sensor register, so please refer to the following formulas for the real exposure
time.
Model
Method
036MI2-WOM Series
Range
:
1~32767(Exposure Time
:
1/33149~0.988 sec)
*1
External trigger value : 2~32767
Exposure Time
=
(Shutter Value×(640+64))×0.0417
[
μsec]
at 24MHz
130MI-WOM Series
Range
:
1~16383(Exposure Time
:
1/35928~0.52 sec)
Exposure Time
=
(Shutter Value×(1280+244)
-
180)×0.020833
[
μsec]
at 48MHz
035IMX-WOM Series
Range
:
1~8191(Exposure Time
:
1/33582~0.24 sec)
Exposure Time
=
(Shutter Value×(1280+328))×0.018519
[μsec]
at 54MHz
300MI-WOM Series
Range
:
1~16383(Exposure Time
:
1/19688~0.832 sec)
Exposure Time
=
(Shutter Value×(2048+390))×0.020833
[
μsec]
at 48MHz
500MI-WOM Series
Range
:
1~16383(Exposure Time
:
1/53452~1.196 sec)
Exposure Time
=
((Shutter Value×(2592+912))
-
2606)×0.020833
[
μsec]
at 48MHz
1000MI-WOM Series
Range
:
1~16383(Exposure Time
:
1/11678~1.4 sec)
Exposure Time
=
(Shutter Value×(3856+254))×0.020833
[μsec]
at 48MHz
1400MI-WOM Series
Range
:
1~16383(Exposure Time
:
1/9756~1.68 sec)
Exposure Time
=
(Shutter Value×(4608+312))×0.020833
[μsec]
at 48MHz
5-3
Operation clock settings
Users can switch the operation clock between 48MHz / 24MHz / 12MHz with the standard viewer software or SDK.
*1 48MHz is not available on ARTCAM-036MI2-WOM series.
*2
ARTCAM-035IMX-WOM series is fixed at 54MHz.