- 31 -
t0
t1
t5
t3
t4
t2
11-1-3
Trigger timing chart(ARTCAM-130MI-WOM/300MI-WOM series)
t0
Input Pulse Width
Above 1ms
t1
Photo Coupler Delay
1~99
μs (Subject to Input Pulse Voltage)
t2
Reset Time
9 * 1H(ARTCAM-130MI series)
18 * 1H(ARTCAM-300MI series)
t3
Exposure Time
Subject to Shutter Speed Settings
t4
Frame Transfer
Subject to ROI Settings and Operation Clock
t5
Effective Trigger for next frame
Approximate 100H after the Vertical Synchronization Signal
transits to a low voltage
*130MI-WOM 1H
=
(1280+244)×0.020833[
μs]
300MI-WOM 1H
=
(2048+390)×0.020833[
μs]
Trigger Input
TRIG Signal
Reset Time
1
st
Line
2
nd
Line
Last Line
Vertical Synchronization Signal
Image Transfer (USB)
Exposure Time