Artistic Licence Engineering Ltd. Micro-Scope 3a user guide
58 / 73
Column
Name
Function
Result
4
Chan
This is the channel address for this lamp
attribute. Numbering is in the range 1 to 38.
5
Offset
This is the minimum value of data that is
valid for this attribute. Normally this is
zero, however some fixtures (the MadScan
for example) mix attributes on a single
channel. If intensity is controlled over the
range 128 to 255, you must enter a value of
128 in this field.
6
Range
This is the range of values of data that is
valid for this attribute. Normally this is
255, however some lamps (the MadScan for
example) mix attributes on a single channel.
If intensity is controlled over the range 128
to 255, you must enter a value of 127 in this
field.
7
Icon
This field is for file compatibility with
Show-Control.The following are the default
abbreviations:
Abbreviation Attribute
P
Pan
T
Tilt
R
Red
G
Green
B
Blue
C
Colour
g
Gobo
I
Intensity
i
Iris
p
Prism
8-58
Palette
This is the default data value for each
attribute of each palette.