Manual explosion-safe SpotLED AR-040
Issue April 2020
5 / 6
Install the connection cable and make sure that it is protected from mechanical and chemical influences.
Connect the end of the cable in a proper way to an external connection box and ensure this is done
professionally. The connection box is not supplied. Use a connection box that it is suitably protected for the
(explosion hazard) classification of the surroundings in which it will be used.
The connection cable has three cores for the following connections:
Green / yellow:
Earth or equipotential bonding
Blue:
Neutral (-)
Brown:
Positive (+)
9.
Maintenance
For the maintenance of the SpotLED the requirements as stated in EN 60079-17 apply.
If the SpotLED and the connection cable are no longer in good condition or are very dirty or damaged they must be
repaired or cleaned immediately.
The power supply to the SpotLED must be switched off and may only be restored after the maintenance has been
carried out and approved.
The advised maintenance cycles for the SpotLED depends on the specific use and must therefore be agreed upon with
the user for the expected use.
10.
Repair
Except for the transparent lens and the bracket, none of the parts of the SpotLED can be repaired or replaced. If
repairs are carried out in an incompetent manner, the explosion-safety of the SpotLED can no longer be guaranteed.
Therefore it is preferred that the SpotLED is returned to the manufacturer for repair.
11.
Removal / re-use
The equipment can be completely processed as electronic waste. For processing regarding disposal or reuse of the
product and its packaging, national disposal and environmental laws and legislation must be taken into consideration.