background image

Manual explosion-safe SpotLED AR-040 

 

Issue April 2020

 

3 / 6 

The cable has a standard length of 5 meters. Due to the stainless steel bracket and the large 155° rotation angle, the 

SpotLED is suitable for mounting against walls or sloping surfaces. 

 

3.

 

Characteristics 

The characteristics of the SpotLED can be summarized as follows: 

 

Robust SpotLED with ingress protection level IP67 

 

Light source: 5 PowerLEDs, 3 Watt each 

 

780 Lumen 

 

Coated aluminum housing, stainless steel bracket, powder coated 

 

Available in two different housing colors 

 

Obtainable in various beam angles with different optics 

 

Provided with a fixed cable 

 

Manufactured on the basis of the European Directive 2014/34/EU (ATEX 114) 

 

Suitable for use in gas and dust hazardous areas classified as zone 2 and 22 

 

Explosion safety category and protection degree against ignition applied: 

II 3 G Ex ec IIC T4 Gc 

II 3 D Ex tc IIIC T135˚ C Dc 

 

Protection degree against the ingress of water and dust IP67 according EN 60529 

 

Suitable for internal and external use 

 

Rotation angle from -50˚ to +105º 

 

4.

 

CE - Marking 

The SpotLED complies to the European Directives for EMC and ATEX and integral to the Low Voltage Directive. 

With regard to explosion safety the SpotLED has been designed and manufactured on the basis of the essential health 

and safety requirements of European Directive 2014/34/EU (ATEX 114) relating to Group II Category 3GD. 

Harmonized European construction standards have been applied fulfilling the essential requirements of the directives. 

For more details refer to section 6 “Technical data” or to the EU Declaration of Conformity on the last page of this 

manual. 

 

5.

 

Application 

The explosion-safe SpotLED series AR-040 have been designed for and are suitable for use in hazardous classified 

areas due to flammable gases, vapors, mist, fibers and dust. Because they are explosion-safe and certified on the 

basis of Group II Category 3GD of the ATEX Directive they are suitable for use in the following types of zones in 

explosion hazardous areas: 

 

for combustible gases, vapors and mist: zone 2 

 

for combustible fibers and dust: zone 22 

The parts used are all manufactured from corrosion resistant materials and are resistant to the effects of most common 

chemicals.  

 

 