User manual 

Explosion-safe window air conditioning system 

Type series AR-054 

 

 

 

II 3 G Ex ic nAC h IIC T3 Gc 

 

 

Содержание AR-054 series

Страница 1: ...User manual Explosion safe window air conditioning system Type series AR 054 II 3 G Ex ic nAC h IIC T3 Gc ...

Страница 2: ...it when it is damaged During installation of the air conditioning unit national safety regulations must be observed Only use the air conditioning unit under the environmental conditions for which it is specified Deviating environmental conditions can contribute to damage to the equipment and may lead to possible danger to the life of the user Do not use the air conditioning unit at temperatures de...

Страница 3: ...l covered by a non metallic hood The electronically driven fan provides air flow on both sides of the system The infra red remote control contains electronics PCB with a display and membrane pushbuttons all housed in a non metallic housing containing two 2 1 5 V DC AAA dry cell batteries The ambient temperature allowed for the apparatus is 20 C to 45 C 3 Characteristics The characteristics can be ...

Страница 4: ...N 60079 11 2012 EN 60079 15 2010 EN 80079 36 2016 and EN 80079 37 2016 Certification document Unit assessment certificate Ambient temperature 20 C to 45 C Sealed against moisture and dust IP54 according to EN 60529 Material housing inside part Sheet steel frame and non metallic cover Material housing outside part Sheet steel plating Connection H07 RN F 3 x 1 5 mm connection cable length 5 meter Ea...

Страница 5: ...g The unit contains no components that need direct access in normal operation The following warning is marked The air conditioning unit is modified to explosion safe meeting ATEX requirements II 3 G No serviceable parts inside Refer to qualified personnel as substitution of parts may impair the suitability for use in hazardous areas The housing may only be opened under non hazardous safe condition...

Страница 6: ...ive for repair If the housing is opened care must be taken of the following The housing must not be opened unless power is switched off prior to repair The housing must not be opened unless the area has been known to be non hazardous If opened the AR 054 air conditioning unit shall be dismantled in a logical sequence 12 Removal re use For processing regarding disposal or reuse of the product and i...

Страница 7: ...Manual explosion safe window air conditioning system AR 054 Issue December 2017 7 7 This document can be subject to change without notice ...