![ARTHUR MARTIN AW6T7242AF Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/arthur-martin/aw6t7242af/aw6t7242af_user-manual_2978109028.webp)
Problem
Possible solution
The appliance makes an
unusual noise and vi‐
brates.
• Make sure the levelling of the appliance is correct. Refer to
"Installation instruction".
• Make sure that the packaging and/or the transit bolts are re‐
moved. Refer to "Installation instruction".
• Add more laundry in the drum. The load may be too small.
The programme duration
increases or decreases
during programme exe‐
cution.
• The SensiCare System is able to adjust the programme dura‐
tion according to the type and the laundry load size. Refer to
"The SensiCare System load detection" in "Daily Use" chap‐
ter.
The washing results are
not satisfactory.
• Increase the detergent quantity or use a different detergent.
• Use special products to remove the stubborn stains before
you wash the laundry.
• Make sure that you set the correct temperature.
• Decrease the laundry load.
Too much foam in the
drum during the washing
cycle.
• Reduce the quantity of detergent.
After the washing cycle,
there are some deter‐
gent residues in the dis‐
penser drawer.
• Make sure that the flap is in the correct position.
• Make sure you have used the detergent dispenser according
the indications given in this user manual.
After the check, activate the appliance. The programme continues from the point of interruption.
If the problem occurs again, contact the Authorised Service Centre.
If the display shows other alarm codes, deactivate and activate the appliance. If the problem
continues, contact the Authorised Service Centre.
TECHNICAL DATA
Dimension
Width/ Height/ Depth/ To‐
tal depth
400 mm/ 890 mm/ 600 mm/ 600 mm
Electrical connection
Voltage
Overall power
Fuse
Frequency
220 - 240 V
2200 W
10 A
50 Hz
Level of protection against ingress of solid particles
and moisture ensured by the protective cover, except
where the low voltage equipment has no protection
against moisture
IPX4
Water supply pressure
Minimum
Maximum
0.5 bar (0.05 MPa)
8 bar (0.8 MPa)
Water supply
1)
Cold water
28