Building In
16
573
21
548
min. 550
20
600
min. 560
558
589
114
594
595 +/-1
3
5
558
21
548
min. 550
20
589
114
16
573
590
min. 560
594
3
5
595 +/-1
Securing the appliance to the
cabinet
A
B
Electrical installation
The manufacturer is not
responsible if you do not follow
the safety precautions from the
Safety chapters.
This appliance is supplied only with a
main cable.
Cable
Cable types applicable for installation or
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-
F, H05 V2V2-F (T90), H05 BB-F
For the section of the cable refer to the
total power on the rating plate. You can
also refer to the table:
Total power (W)
Section of the ca‐
ble (mm²)
maximum 1380
3 x 0.75
maximum 2300
3 x 1
maximum 3680
3 x 1.5
The earth cord (green / yellow cable) must
be 2 cm longer than phase and neutral
cables (blue and brown cables).
31
Содержание AKM5641PAX
Страница 1: ...AKM5641PAX EN Oven User Manual 2 DE Backofen Benutzerinformation 34 ...
Страница 69: ...69 ...
Страница 70: ...70 ...
Страница 71: ...71 ...
Страница 72: ...867340919 B 202017 ...