background image

6

SAFETY INSTRUCTIONS

Plugs

•  Do not dismantle any part of the device's power connector.
•   Disconnect the power plug from the AC outlet when the device is not 

going to be used for an indefinite period of time.

Power and extensions cords

•   Use the appropriate power cord with the correct plug type.
•   Do not overload wall outlets or power cords.
•   Make sure the total ampere passed through an extension cord does not  

exceed the maximum allowed by the cable used.

•   Do not place anything on the power cord.
•   Do not locate this product where a person may walk or trip over the 

cord.

EC REGULATIONS AND SECURITY

ATTENTION: Do not disassemble or modify the device in any way. 
This symbol warns of the presence of dangerous un-insulated 
voltages inside some of the components, of sufficient magnitude 
to expose people to risk of electronic shock.

This symbol draws attention to important use and maintenance 
instructions in the manual that accompanies the unit.

This symbol indicates that the equipment conforms to the norms 
established by the European Community.

This symbol indicates the power supply. 

Содержание DynamicVision

Страница 1: ...User Guide Danish craftmanship Mediterranean soul Technology Serving Desing DynamicVision Motorised wall mount for video conference cameras ...

Страница 2: ......

Страница 3: ...F CONTENTS EC REGULATIONS AND SECURITY 6 SAFETY INSTRUCTIONS 6 SYSTEM DESCRIPTION 8 INSTALLATION 10 INPUT CONNECTORS 12 CONTROLS 13 AHNET PROTOCOL 14 INFORMATION ON DISPOSAL 16 WARRANTY TERMS AND CONDITIONS 17 ...

Страница 4: ... integration and for a maximum reliability Please read this installation and operating instructions carefully and keep them in a safe place for future reference We remain at your entire disposal if you have any suggestions that would help us improve our products Henrik Holm General Manager hholm albiral com ...

Страница 5: ... based on quality materials and the latest technology Products which endow meeting and conference rooms with silent ergonomic innovative and aesthetic solutions that integrate into the furniture hang from the walls as works of art or are used as interactive points of information The world of Arthur Holm Arthur Holm offers a selection of unique elegant versatile flexible and ergonomic products that...

Страница 6: ...e cable used Do not place anything on the power cord Do not locate this product where a person may walk or trip over the cord EC REGULATIONS AND SECURITY ATTENTION Do not disassemble or modify the device in any way This symbol warns of the presence of dangerous un insulated voltages inside some of the components of sufficient magnitude to expose people to risk of electronic shock This symbol draws...

Страница 7: ...trical outlet must be in an easily accessible place Environment Install the equipment on vertical surface Install the equipment in a ventilated area Avoid exposing the equipment to Rain or water Excessive heat cold or humidity Area exposed to direct sunlight Dirty areas Equipment generating strong magnetic fields Avoid placing open containers of liquid near the equipment To prevent damage the equi...

Страница 8: ...le improving the interior design of the conference room with its easily adaptable front enclosure that can be covered with various materials The pre installation frame is the perfect solution to coordinate between system integrators architects or constructors The camera enclosure is activated via RS 422 infrared or AHlink when needed It neatly stores the camera away when not required both protecti...

Страница 9: ...all mount enclosure for videoconference cameras Downward moving cover Controls AHlink AHnet RS 422 and Infrared remote control Box Contents Before the installation of your retractable system please check the contents of the shipping box it must contain the following items Motorised lift system Power cord Remote control Power supply 100 240Vac 50 60Hz Output 12V User Manual Important note This devi...

Страница 10: ...ount on any wall Installation is extremely simple Attach the enclosure into the hole previously made Use suitable hardware in the 4 holes Once the system connections are done match the front cover to the enclosure clipping in the pressure staples Then press until they clip ...

Страница 11: ...ng camera to the platform with the most appropriate screws under the camera model If you have any questions please ask the video conference camera s manufacturer Push the control button on the remote control to lift the cover The DynamicVision s cover will then open and the tray will move horizontally outward Place now the platform with the camera already fixed and connected recommended in the Dyn...

Страница 12: ...rmination Activate ON the termination ONLY on the last device of the RS422 bus GPI External contact close control SubD9 female 1 GPI1 2 GPI1 3 GPI2 4 GPI2 5 GPI3 6 GPI3 7 N C 8 12Vdc 600mA max 9 Ground Use GPI1 1 12Vdc 2 Ground to open the device Use GPI3 6 12Vdc 5 Ground to close the device 12V D C Power supply input connector XLR 4 connector 1 2 Ground 3 4 12Vdc Service Use USB only for service ...

Страница 13: ...also no obstructions on its path Push the down arrow to close the front cover Please be sure that there is nothing that may obstruct the path of the device s vertical movement While the cover moves downward covering the video conference camera the tray that supports the video conference camera retracts into the enclosure Please be sure that there are also no obstructions on its path Push the right...

Страница 14: ... the App Store IOS system or from Google Play Android system The App is free Execute the AHlink on your mobile phone On the AHlink App options it is recommended to not select Auto Connect and select Portrait on Orientation To connect to the device select Scan for local devices ...

Страница 15: ...ess right narrow on remote IR controller The AHlink name always begins with AH characters and the fourth last MAC AHlink address Select the device to control and set up the unit When selecting the device the first page will upload This page is used to check the device and for basic installation set up ...

Страница 16: ...mation of the last AHnetcommand received from RS 422 port SENSORS Indicates sensor status S1 indicates the inside tray position S2 indicates the outside tray position S3 indicates the open cover position S4 indicates the close cover position AHNET ADDRESS Indicates the AHnet ID selected on the control board PASSWORD Password needed to enter on technical configuration page ...

Страница 17: ... 8 NC Connection PINS 1 2 The units respond PINS 3 6 The units receive instructions Protocol to control the device by addressable RS422 bus You can connect up to 30 devices on the same RS422 bus You can use AH Interface ETR to control the RS422 bus The units should have a set address and the address must start by 1 From the ERT to the last device on the AHnet the maximum cable length between ends ...

Страница 18: ...N FB XX 01 00 00 FA XX 14 00 00 INQUIRY CONTROL BYTE FB XX 14 CB1 CB2 XX Number of the device address Up to 30 devices for each RS422 BUS CB1 Response in 8 bites of the device status CB2 Response in 8 bites of the device status CB1 BITE 7 6 5 4 3 2 1 0 CLOSED 1 1 0 1 OPENED 0 1 0 1 PROTECTION STOP 1 EQUIPMENT OK 0 To send an order to all the devices you must use the address 249 Dec Byte1 F9 Hex By...

Страница 19: ...ll help save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordance with national legislation For business users in ...

Страница 20: ...splay Solutions Although Albiral Display Solutions S L pays for freight and insurance costs Albiral Displays Solutions will not be responsible for any damages caused by the transportation of the goods if the customer does not inform in writing when receiving the goods 5 2 After 90 days of the purchase date the beneficiary of the warranty will pay both freight and insurance costs Albiral Display So...

Страница 21: ... there are no damages during transportation 8 The warranty is not valid if the beneficiary of the warranty does not include a RMA form and a copy of the purchasing invoice Please note that laws vary from country to country and the same provisions of this warranty may not apply to you If you have any doubts concerning the terms of this warranty please contact business albiral com 34 938 502 376 Cop...

Страница 22: ...22 ...

Страница 23: ...Sant Hipòlit de Voltregà 08512 Barcelona Spain tel 34 93 850 23 76 23 83 fax 34 93 850 25 50 23 72 web www arthurholm com e mail marketing arthurholm com This manual can be modified without previous notice ENG August 2020 P27178ITEP P27178RUPC P27178USPC P27284DEEP P27284EPPC P27284ESEP P27284GBEP P27284RUPC P27284USPC P27715ESEP P28089DEEP P28089ESEP P28089ITEP P28089USPC P28090EP00 P31160ESES P3...