MONITOR AHnet PROTOCOL
Communications protocol
COMMUNICATION RS422
CONNECTION
RJ45
WIRING
CAT-6
Speed and configuration
BAUD RATE
38400
DATA BITS
8
PARITY
NONE
STOP BITS
1
Wiring Diagram
1. Data TX +
2. Data TX –
3. Data RX +
4. NC
5. NC
6 .Data RX –
7. NC
8. NC
Connection
PINS 1 & 2
The units respond
PINS 3 & 6
The units receive instructions
Protocol to control the monitor by addressable RS422 bus.
You can connect up to 30 monitors on the same RS422 bus.
You can use an AH ERT interface, to control the RS422 bus.
The units should have a set address and the address must start by 1.
Maximum cable length between ends: 500 m/1640 ft.
RJ-45