12
11.
DMX protocols
Configuring DMX is described “Setting the DMX mode” on page 11.
Channel
Value
Function
4CH
10CH
12CH
1
1
*
Red :
0-255
Red dimmer
2
2
*
Green :
0-255
Green dimmer
3
3
*
Blue :
0-255
Blue dimmer
*
*
1
Row1 Red :
0-255
Row1 Red dimmer
*
*
2
Row1 Green :
0-255
Row1 Green dimmer
*
*
3
Row1 Blue :
0-255
Row1 Blue dimmer
*
*
4
Row2 Red :
0-255
Row2 Red dimmer
*
*
5
Row2 Green :
0-255
Row2 Green dimmer
*
*
6
Row2 Blue :
0-255
Row2 Blue dimmer
*
4
7
Dimmer :
0-255
All dimmer
*
5
8
Strobe :
0-9
No function
10-255 Strobe
*
6
9
Auto :
5
Do not look directly at the light source from close range.
Take precautions to prevent injury due to falls when working at height.
For permanent installation, ensure that the fixture is securely fastened to a
load-bearing surface with suitable corrosion-resistant hardware.
For temporary installation with clamps, ensure that the quarter-turn
fasteners are turned fully and secured with a suitable safety cable. The
cable must be approved for a safe working load (SWL) of 10 times the
weight of the fixture, and it must have a minimum gauge of 3 mm.
3.
Parts identification and terminology
A Seetronic IP65 sockets
B 1008 LEDs
C LCD display
D Control panel
E Seetronic IP65 sockets
F Connection cable
G Base bracket
H Base
I Safety wire eyelet
J Colling fans
K Tilt lock
L Tilt lock
WARNING!
Take measure to prevent personal injury.