ARTEX PRODUCTS / ACR ELECTRONICS, INC.
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
DGL-1, DONGLE (453-4010)
570-4010 Rev. G
Company Confidential
Page 23 of 30
NOTE:
Remote switch pin numbers are for an ARTEX standard remote switch (P/N
345-6196-04).
5)
Terminate wires from the horn and remote switch with the male terminal pins provided (P/N 151-6627).
a)
Strip approximately 0.15 in. (3 mm) of insulation from ELT receptacle end of the wires from the horn
and remote switch.
b)
Dress and tin the bare wire ends to prevent the strands from fraying during terminal crimping
operations.
c)
Install the terminal pins with a Molex crimp tool (Molex Tool P/N 63811-330), or equivalent.
6)
Insert the terminated wires into the applicable locations in the rectangular 12 position connector.
7)
Fabricate a power wire of sufficient length to reach from the red, un-terminated wire on the
preassembled wire harness to a suitable ai28VDC, switchable power source. See Figure 7 Molex
Power and Ground Wires on page 23.
CAUTION
:
DO NOT WIRE DONGLE DIRECTLY TO THE AIRCRAFT BATTERY. THE 28
VOLT DC POWER SOURCE SHOULD BE PROTECTED WITH A .5A FUSE, OR
CIRCUIT BREAKER, AND ON A SWITCH BUS.
a)
A Raychem solder sleeve splice (Raychem P/N D-1744-01) is provided for this connection.
NOTE:
Refer to Raychem for specific instructions on the splice use. Alternate splices may be
used if installed in accordance with FAA AC 43.13.1A, Section 445, Splices in Electrical
Wire.
8)
Connect the +28VDC power source to the red wire.
Figure 7 Molex Power and Ground Wires
9)
Connect the ground to the black, un-terminated wire.
NOTE:
Refer to Raychem for specific instructions on the splice use. Alternate splices may be
used if installed in accordance with FAA AC 43.13.1A, Section 445, Splices in Electrical
Wire.
a)
A Raychem solder sleeve splice (Raychem P/N D-1744-01) is provided for this connection.
b)
For installations of an ELT/Dongle, splice the black wire to an aircraft ground point near the ELT. See
Figure 8 Dongle Wiring Diagram on page 24.
NOTE:
Pin 11 will not be available for remote switch grounding with the Dongle/ELT
installation. Slice a ground for the remote switch.