ARTEX PRODUCTS / ACR ELECTRONICS, INC
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
C406-2 (453-5000), C406-2HM (453-5001)
570-5000 Rev. U
Company Confidential
25-62-11
Page 21 of 66
continuously, but sounds at predetermined intervals and runs for shorter periods toward the end of
ELT battery life.
SUBTASK 25-62-11-870-002
B.
Normal Operation
1)
The cockpit remote switch is in the “ARM” position (i.e., down).
2)
The local switch on the ELT is in the “OFF” position (i.e., down).
SUBTASK 25-62-11-870-003
C.
Manual Activation
1)
The ELT may be manually activated by placing either the remote switch or the ELT local switch in the
“ON” position.
NOTE:
As long as the cockpit remote switch and the ELT local switch are in the ARM/OFF
positions respectively, the ELT will automatically activate on impact.
SUBTASK 25-62-11-870-004
D.
ELT Reset
1)
If the ELT is activated accidentally, it will need to be reset.
2)
Reset the ELT from the cockpit by moving the remote switch to the “ON” position, waiting
approximately one second, and then moving it back to the “ARM” position. If the switch is already in
the “ON” position, move it to the “ARM” position.
3)
Reset the ELT locally by moving the switch on the ELT to the “ON” position, waiting approximately
one second, and then moving it back to the “OFF” position. If the switch is already in the “ON”
position, move it to the
“OFF” position.
NOTE:
The ELT cannot be reset if either the cockpit remote switch or the ELT local switch is
in the “ON” position.
SUBTASK 25-62-11-750-001
E.
Functional Check
1)
A monthly functional check is recommended to verify operational status of the ELT.
2)