Programming Model
MVME2502 Installation and Use (6806800R96D
)
146
24
BOOT ROM
Location
TSEC1_TXD[6:4],
TSEC1_TX_ER
011X
On-chip boot ROM-SPI
configuration (x=0),
SDHC (x=1)
25
Host/Agent
Config
LWE1/LBS1,
LA[18:19]
111
The processor acts as the
host/root complex for all
PCI-E/Serial Rapid IO
interfaces (default).
26
I/O Port Select
TSEC1_TXD[3:1],
TSEC2_TX_ER
0010
PCI-E 1 (x1) (2.5 Gbps) -
SerDes lane 0
PCI-E 2 (x1) (2.5 Gbps) -
SerDes lane 2
PCI-E 3 (x2) (2.5 Gbps) -
SerDes lane 2-3
27
DDR SDRAM
TYPE
TSEC2_TXD1
1
DDR31.5 V. CKE low at
reset (default)
28
SerDes PLL Time
Out Enable
TRIG_OUT
1
Disable PLL lock time-out
counter. The power-on-
reset sequence waits
indefinitely for the SerDes
PLL to lock (default).
29
System Speed
LA[28]
1
SYSCLOCK is above 66
MHz
30
SDHC Card
Detect Polarity
TSEC2_TXD_5
1
Not Inverted
31
RAPID System
Size
Default
RapidIO is not used
Table 7-1 POR Configuration Settings (continued)
CONFIG
CONFIG PINS
CONFIG
SELECTION
REMARKS
Содержание MVME2502
Страница 1: ...MVME2502 Installation and Use P N 6806800R96D December 2014 ...
Страница 12: ...MVME2502 Installation and Use 6806800R96D 12 List of Tables ...
Страница 14: ...MVME2502 Installation and Use 6806800R96D 14 List of Figures ...
Страница 20: ...MVME2502 Installation and Use 6806800R96D About this Manual 20 About this Manual ...
Страница 30: ...MVME2502 Installation and Use 6806800R96D Sicherheitshinweise 30 ...
Страница 38: ...Introduction MVME2502 Installation and Use 6806800R96D 38 Figure 1 3 Serial Number Location ENP2 Variant ...
Страница 52: ...Hardware Preparation and Installation MVME2502 Installation and Use 6806800R96D 52 ...
Страница 54: ...Controls LEDs and Connectors MVME2502 Installation and Use 6806800R96D 54 Figure 3 2 Board Layout ENP2 Variant ...
Страница 108: ...Functional Description MVME2502 Installation and Use 6806800R96D 108 ...
Страница 142: ...Boot System MVME2502 Installation and Use 6806800R96D 142 ...
Страница 154: ...Programming Model MVME2502 Installation and Use 6806800R96D 154 ...
Страница 156: ...Replacing the Battery MVME2502 Installation and Use 6806800R96D 156 Figure A 2 Battery Location ENP2 Variant ...
Страница 162: ...Related Documentation MVME2502 Installation and Use 6806800R96D 162 ...
Страница 163: ......