MaxCore™ MC3000 Platform AC-Quick Start Guide

Artesyn Embedded Technologies
Marketing Communications
2900 S. Diablo Way, Suite 190
Tempe, Arizona 85282

Artesyn Embedded Technologies
Lilienthalstr. 17-19
85579 Neubiberg/Munich
Germany

Connect to CPU over ttyS 

(COM) port (Cont’d)

3. Terminate the 

ttyS

 session by pressing <ESC 

+ T> at the beginning of a line. It will take 
you back to the BMC OS prompt.

Alternatively, you can connect to the 

ttyS0

/

COM1

 port of each CPU with an USB cable 

between your PC and the microUSB CONSOLE 
connector at the card bracket. As soon as your 
target CPU is powered, PC provides two new 

ttyS

/

COM 

devices. The default settings are 

38400 

buad rate, 

8

 bits, 

no

 parity, 

no

 flow con-

trol. The BIOS is always visible on this port. Your 
OS must be configured to use this port.

12

Connect to SSF on Shelf 

Host (Cont’d)

2. Connect to 

172.26.1.2

 from the PC browser 

and login with 

Username

Admin

 and 

Pass-

word

Admin

You will see the SSF console for remote man-
agement. The left frame shows a tree struc-
ture with all resources. Select a resource and 
the right frame will show information and 
action buttons.
Click 

Software Upate

 button to know infor-

mation about the installed firmware and soft-
ware and also provide the tools for updates. It 
is recommended to update each new Max-
Core now.

For information about documentation available, 
refer to 

Product Documentation Overview

 

chapter in 

MaxCore™ MC3000 Platform Installation 

and Use 

manual.

You can download the 

Getting Started with Max-

Core™ MC3000 Application Note

 from https://

www.artesyn.com/computing/products/prod-
uct/max-core. This helps you to get familiar with 
MaxCore and you can also find other MaxCore 
related documentation.

Whenever you are going to install Artesyn’s PCIE 
cards, refer to the respective release notes of the 
card. Contact your local Artesyn sales executive.

13

Connect to SSF on Shelf 

Host

System Services Framework (SSF) represents the 
front door entry into MaxCore. It provides access 
to all application relevant resources including 
the PCIe cards. SSF is executed by the Shelf Host 
and is supported by the BMC. 

To connect SSF on Shelf Host: 
1. Unplug the cable from 

BMC

 and plug it into 

the 

ETH4

 connector on the IO Panel on the 

front of the system. 

Note

: The 

ETH4

 connector supports 1G and 

10G link speed. It does not support 100M link 
speed. Check if your PC supports 1G link 
speed, otherwise place a 1G switch between 
PC and 

ETH4

.

13

Single PC for BMC and Shelf

You can connect your PC to BMC and Shelf Host 
with a single cable using the following steps:
1. Connect your PC to MegaRAC (as described in 

Step 9). 

2. Go to 

Configuration

 > 

Network

 to modify 

Network Settings

.

3. Select 

eth0

 from the 

LAN Interface

 drop-

down list.

4. Change the 

IPv4 Address

 to

172.26.1.1

5. Change the 

Subnet Mask

 to 

255.255.0.0

6. Set the 

Default

 

Gateway

 to 

172.26.0.254

7. Save the configuration and shut down the 

system and disconnect it from the main 
power for at least 10 seconds.

8. Unplug the PC from 

BMC

 and connect it to 

ETH4

Note

: Make sure your PC has a port 

with 1G link speed.

Now, your PC can communicate with BMC and 
ShelfHost over 

172.26.1.1

 and 

172.26.1.2

172.26.1.5

 is a safe IP address for your PC. 

Note

:This connection supports everything, 

except a remote power up of MaxCore. This can 
be done over the BMC connector only.