Connect to CPU over ttyS
(COM) port (Cont’d)
3. Terminate the
ttyS
session by pressing <ESC
+ T> at the beginning of a line. It will take
you back to the BMC OS prompt.
Alternatively, you can connect to the
ttyS0
/
COM1
port of each CPU with an USB cable
between your PC and the microUSB CONSOLE
connector at the card bracket. As soon as your
target CPU is powered, PC provides two new
ttyS
/
COM
devices. The default settings are
38400
buad rate,
8
bits,
no
parity,
no
flow con-
trol. The BIOS is always visible on this port. Your
OS must be configured to use this port.
12
Connect to SSF on Shelf
Host (Cont’d)
2. Connect to
172.26.1.2
from the PC browser
and login with
Username
:
Admin
and
Pass-
word
:
Admin
You will see the SSF console for remote man-
agement. The left frame shows a tree struc-
ture with all resources. Select a resource and
the right frame will show information and
action buttons.
Click
Software Upate
button to know infor-
mation about the installed firmware and soft-
ware and also provide the tools for updates. It
is recommended to update each new Max-
Core now.
For information about documentation available,
refer to
Product Documentation Overview
chapter in
MaxCore™ MC3000 Platform Installation
and Use
manual.
You can download the
Getting Started with Max-
Core™ MC3000 Application Note
from https://
www.artesyn.com/computing/products/prod-
uct/max-core. This helps you to get familiar with
MaxCore and you can also find other MaxCore
related documentation.
Whenever you are going to install Artesyn’s PCIE
cards, refer to the respective release notes of the
card. Contact your local Artesyn sales executive.
13
Connect to SSF on Shelf
Host
System Services Framework (SSF) represents the
front door entry into MaxCore. It provides access
to all application relevant resources including
the PCIe cards. SSF is executed by the Shelf Host
and is supported by the BMC.
To connect SSF on Shelf Host:
1. Unplug the cable from
BMC
and plug it into
the
ETH4
connector on the IO Panel on the
front of the system.
Note
: The
ETH4
connector supports 1G and
10G link speed. It does not support 100M link
speed. Check if your PC supports 1G link
speed, otherwise place a 1G switch between
PC and
ETH4
.
13
Single PC for BMC and Shelf
You can connect your PC to BMC and Shelf Host
with a single cable using the following steps:
1. Connect your PC to MegaRAC (as described in
Step 9).
2. Go to
Configuration
>
Network
to modify
Network Settings
.
3. Select
eth0
from the
LAN Interface
drop-
down list.
4. Change the
IPv4 Address
to
172.26.1.1
5. Change the
Subnet Mask
to
255.255.0.0
6. Set the
Default
Gateway
to
172.26.0.254
7. Save the configuration and shut down the
system and disconnect it from the main
power for at least 10 seconds.
8. Unplug the PC from
BMC
and connect it to
ETH4
.
Note
: Make sure your PC has a port
with 1G link speed.
Now, your PC can communicate with BMC and
ShelfHost over
172.26.1.1
and
172.26.1.2
.
172.26.1.5
is a safe IP address for your PC.
Note
:This connection supports everything,
except a remote power up of MaxCore. This can
be done over the BMC connector only.