MaxCore™ MC3000 Platform AC-Quick Start Guide

Artesyn Embedded Technologies
Marketing Communications
2900 S. Diablo Way, Suite 190
Tempe, Arizona 85282

Artesyn Embedded Technologies
Lilienthalstr. 17-19
85579 Neubiberg/Munich
Germany

Connect to MegaRAC on 

BMC

The Baseboard Management Controller (BMC) 
device provides the backdoor entry into MaxCore. 
This back door is a web server with remote access 
to the power button, other chassis infrastructure 
and to the Shelf Host CPU. This is available even 
when the main power is switched off.
1. Connect your PC to the RJ45 labeled 

BMC

 on 

the IO Panel on the front of the system.

2. From the PC browser, connect to 

192.168.201.9

 and login with 

Username

 and

 

Password

 as 

admin/admin.

The MegaRAC con-

sole for remote management is displayed.

For more details on MegaRAC, refer to the 

Max-

Core™ MC3000 Platform Installation and Use

 man-

ual.

9

Power up MaxCore CPUs

Make sure that the system has been located in a 
place with room temperature for at least 24 
hours before powering it up.
There are two options to switch on the main 
power.
• Push the 

PWR

 button at the MaxCore front 

shortly. For this, a tool like a pen is needed.

• In 

MegaRAC 

application,

 

go to

 Remote Con-

trol 

>

 Server Power Control

, select 

Power 

On Server 

and then click

 Perform Action

 

button to power up the box remotely.

10

Connect to Shelf Host over 

VGA

Like a PC, the Shelf Host has access to a built-in 
VGA graphics. The display is provided by MegaRAC 
and the remote connection establishes over Ether-
net. There is no VGA cable connector provided by 
MaxCore. 
To connect to Shelf Host over VGA:
1. Connect your PC to the 

BMC

 connector and 

login to MegaRAC (as described in Step 9).

2. Click the 

Launch

 button on the 

Dashboard

 and 

follow the instructions that pop up.
You will be asked to install or update a Java 
engine on your PC and also to change the secu-
rity settings of that Java engine.

When everything is setup correctly, a 

Jviewer

 win-

dow will launch, which shows the output of the 
VGA graphics. 

11

Connect to CPU over ttyS 

(COM) port

Other CPUs in MaxCore do not have access to 
the built-in VGA graphics, but the console 
access is provided over the serial ports. This is 
required to configure the BIOS and to access a 
CPU without network connectivity. 

To connect to CPU over ttyS (COM) port:
1. Use a terminal emulator on your PC (you can 

load one from http://www.putty.org/) to 
open an

 ssh 

session on the BMC. Use the 

same IP address and the login credentials as 
for MegaRAC as described in Step 9.

2. Execute the following command to open a 

serial console session to a CPU in MaxCore.

$/conf/sol <slotID> <cpuID>

Replace the 

slotID

 with a slot number 

between 1 and 15 and 

cpuID

 with 1 or 2 for 

one of the two CPUs in the same slot.
You are now connected to the 

ttyS1/COM2

 

port of the selected CPU. 

Press <Enter> one or two times to get an out-
put from the OS. If the display remains dark, 
it means either the target CPU is not pow-
ered or the OS responds to 

ttyS0/COM1

which is available at the microUSB connector 
at the card panel.

12

Power up MaxCore CPUs 

(Cont’d)

Note

: You will hear fans spinning up and calming 

down after a while. The main CPU of MaxCore, the 
Shelf Host, will now boot. Allow it to finish booting, 
which may take few minutes.

For more details about BMC and its web interface, 
refer to 

Operation and Maintenance

 chapter in 

Max-

Core™ MC3000 Platform

 

Installation and Use 

manual.