10
DLC910 Function Module Installation and Operations Manual
DLC910 Function Module
Monitoring DLC910 Operations
This section describes how to monitor DLC910 operations using the front and rear panel status LEDs or
DigiLink Manager and contains the following topics:
•
Using the Module Status LEDs (page 10)
•
Using the Module Status LEDs
This section describes how to monitor the module’s operations using the front and rear panel LEDs and
contains the following topics:
•
Understanding the Front Panel Status LEDs (page 10)
•
Understanding the Rear Panel Status LEDs (page 11)
Understanding the Front Panel Status LEDs
describes the states of the DLC910 front panel status LEDs as shown in
Figure 6.
DLC910 Front Panel Status LEDs
Table 2.
DLC910 Front Panel Status LEDs
LED
Indicates . . .
State
Description
OK
Module status
Off
No power or unprogrammed.
Green
Normal operation.
Yellow
Minor alarm condition exists.
Yellow (flashing)
Field upgrade in progress.
Red
Major alarm condition exists.
QUADRANT
1, 2, 3, 4
Input status
Off
Not enabled.
Green
Valid SDI signal detected.
Yellow
Enabled but no valid input signal detected.
Red
Unsupported input signal detected.