Monitoring the DLC170AD Operations
You monitor the operation of the DLC170AD using the status LEDs and monitor jack located on the front panel
of the modules (see
Figure 13.
DLC170AD Status LEDs and Monitor Jack
Note:
You can also use Artel’s element management system, DL Manager, to monitor the module
operations (see the
DL Manager Setup and Operations Manual
).
This section contains the following topics:
•
Understanding the DLC170AD Status LEDs (page 18)
•
Using the DLC170AD Monitor Jack (page 20)
Understanding the DLC170AD Status LEDs
describes the different states of the DLC170AD status LEDs as shown in
.
Table 6.
DLC170AD Status LEDs
LED
Indicates . . .
State
Description
Alarms
Action
OK
(also
located on
the rear
panel (see
))
The DLC170AD
status
Off
If power is applied to the system,
an internal fault with the
DLC170AD may exist.
None
Replace the DLC170AD.
Green
Normal operation.
None
Check other Status LEDs.
Yellow
If no other status LEDs indicate a
minor alarm, then a temperature
alarm is indicated.
Minor
Check for adequate inlet
and exhaust airflow.
Red
Major alarm exists that requires
immediate attention. TX status
LED may provide fault
information. If not, the alarm
may be the result of an internal
error.
Major
Address the problem
indicated by the TX status
LED if one exists. If not,
replace the DLC170AD.