ARTE ©
fireplace
|COSY LINE
I
NSTALLATION MANUAL
&
USER GUIDE
4
Fig. 1
Fig. 2
3.
Flue
Fig. 3: Correct position for the flue and chimney cap
fig. 4: Correct position for flat roof
Fig. 5: Chimney on an outside wall
•
Firstly, verify the suitability of the flue
•
If the flue has been used previously, it is necessary to clean it before using the fireplace.
•
It is important to cover the flue, throughout its height, with insulating material like rock wool or fiberglass,
with 3cm thickness minimum.
•
Build the chimney taller than the tallest part of the roof. The right flue dimensions are described in Fig. 3
•
On the roof, if there is more than one flue on the same roof then the minimum distance must be kept
between them, greater than 2m at X-axis and 0.5m at Y-axis (Fig. 3).
•
For a flat roof: the minimum chimney height above any obstruction like walls or another chimney is
0.5m (Fig. 4)
•
For a slopping roof: the minimum chimney height above the ridge(the upper point) is 0.5m (Fig. 6)
Grid
Bottom