![ArSilicii AL320 Series Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/arsilicii/al320-series/al320-series_manual_2976879009.webp)
ArSilicii v041113
9
This contains the items of the menus related with the roof supply of the motorhome.
The bars around the icon are only shown in the event of an electrical fault related with the upper
part of the electric system. The beams indicate that the ceiling lights or in any case the loads
connected to the ceiling distributor output are being supplied.
LIGHTS: ON/OFF
This allows you to switch on or off all the loads connected to the vehicle roof distributor output.
Initially this item of the menu is at ON.
PROBLEMS: NO/SC
This indicates whether there are electrical problems in the ceiling or not (NO = no problem, SC =
Short Circuit). Any symbol next to the wording SC provides extra information for locating the short
circuit. In particular the following symbols are followed (Figure 13):
B
C
D
A
Figure 13
A
Short circuit on the floor distributor left channel
B
Short circuit on the floor distributor right channel
C
Short circuit on the ceiling distributor left channel
D
Short circuit on the ceiling distributor right channel
In the event of more than one source of short circuit there is the combination of the symbols shown
above. As mentioned previously, when the cause of the short circuit ceases, the warning ceases and
the systems resume correct operation without fuse replacement.
LEVELS
This contains the items of the menus related with the tanks.
The bars can indicate: lack of fresh water or overflow of one of the recovery tanks.
FRESH:
X
%
This item of the menu shows the level of the fresh water tank expressed in percentage of the total
volume. (for a probe with 4 levels (0%-30%-60%-90%)