ArSilicii AL320 Series Скачать руководство пользователя страница 15

ArSilicii v041113

 

 

15

FEATURES OF POWER SUPPLY UNIT Model AL320X 

Model AL320X 

The power supply unit model AL320X is a device conceived for energy management; it is 
characterised by being able to switch and regulate the various sources of energy available, 
supplying stable and safe power on the outputs. 
In an motor caravan we typically have the following sources of energy: 
 

1.

 

Engine battery/ies; 

2.

 

Services battery/ies; 

3.

 

Alternator; 

4.

 

External electrical network; 

5.

 

Solar panels; 

6.

 

Generator; 

7.

 

Alternative sources (Wind, etc..) 

 
The typical outputs are considered: 
 

1.

 

Services (the whole living quarters at 12 V) 

2.

 

Fridge 

Specifications  

Electrical 

The electrical specifications of the device are: 

 

Supply voltage: 110-220 V, 50-60 Hz. According to regulations 

 

Rated power: 240 VA .  

 

Services output : 30 Ampere. 

 

Fridge output : 20 Ampere. 

 

SMART active protections. 

 

If connected to the outside 110/220V network, the power supply unit delivers power 
even if the batteries are not connected 

 

Main switch  

 

Warning Led

1

 

Size 

Container: 220x195x82 Weight Kg. 1.5 

Connections 

-  AMP Mate-N-Lok 3x1 connector for connecting to the 110/220 V outside network, with 

selector. 

 

-

 

J1 

molex caimano mlx 94213 - 2014

 (connector “S” used for connecting the services 

battery) 

- contact No.4 

Æ

 Negative 

- contact No.3 

Æ

 Not Used 

- contact No.2 

Æ

 Positive (+12) 

                                                 

1

 See meaning in the Warning Led section below 

Содержание AL320 Series

Страница 1: ...______________________________________ 17 Solar panel_______________________________________________________________________________ 17 Warning Led L1 in Figura 2 new feature _________________________...

Страница 2: ...re 1 Their function varies depending on the context we are in and is described below Figure 2 The Figure 2 buttons allow you to scroll the icons horizontally after selecting an icon to set the status...

Страница 3: ...e functions connected with these keys in detail P1 Allows you to cut off or supply energy to all the users thus it is actually a true main switch The light on means that the electric system is powered...

Страница 4: ...e called icons Immediately below there are two lines of alphanumerical characters Line 1 and Line 2 which describe the various items of the menus selected At the sides of the LCD display there are gra...

Страница 5: ...y The parts that form an icon like the one in Figure 7 are The Main Body the tap indicates the function in this case the water pump The Secondary Body water shows whether the function is operating or...

Страница 6: ...appears in the form of alphanumerical characters In this case the word PUMP is shown line 1 and its ON OFF status line 2 Figure 9 Using the navigation keys Figure 9 the menu items can be scrolled PUMP...

Страница 7: ...ned selecting the associated symbol and consulting all the menus it contains Bar 3 Bar No 3 Bar 3 indicates the instantaneous absorption of the system by the service battery Its filling takes place co...

Страница 8: ...e of short circuit on the pump The running water indicates that the pump is ON PUMP ON OFF This allows you to set the on or off status of the water pump Initially this item of the menu is at OFF PROT...

Страница 9: ...ion for locating the short circuit In particular the following symbols are followed Figure 13 B C D A Figure 13 A Short circuit on the floor distributor left channel B Short circuit on the floor distr...

Страница 10: ...d ON flashing means that the sensor is warming up and is therefore unable to detect an alarm situation The word ON stops flashing when warm up has been completed The word GAS appears when an alarm sit...

Страница 11: ...ery TEMPERATURES Functions that can be activated through suitable optional kits This contains the items of the menus that indicate the momentary value of the inside and outside temperatures IN TEMP X...

Страница 12: ...power unit begins to reduce the power delivered to prevent damage As soon as the temperature returns to normal the power unit resumes normal operation with no external intervention FAST ON OFF Allows...

Страница 13: ...at it is off therefore any flow of energy deriving from the solar panel is not allowed SOLAR P ON OFF This allows you to turn the solar panels on or off Panel ON OFF POWER X VA This gives the power ra...

Страница 14: ...e battery and of the services battery so that the batteries reduce self discharging Do not use chemical substances cleaning solvents or strong detergents to clean the control panel Clean using a sligh...

Страница 15: ...the whole living quarters at 12 V 2 Fridge Specifications Electrical The electrical specifications of the device are Supply voltage 110 220 V 50 60 Hz According to regulations Rated power 240 VA Servi...

Страница 16: ...e AES Fridge contact No 4 Negative contact No 3 Positive 12 Power contact No 2 Positive 12 Low Power contact No 1 Input for any sound devices J5 Amp Mate N Lock 2x1 connector P used for connecting the...

Страница 17: ...t or leave the solar panel connected in the absence of the service batteries Carry out any maintenance with the outside 220 V network connected Solar panel See application note Warning Led L1 in Figur...

Страница 18: ...3 4 1 J2 J3 J5 J1 J4 2 1 Figure 1 Connector layout Figure Layout of contacts and warning lights Fuseless Switching Motorhome Power Unit P2 by ArSilicii P1 S3 S2 S1 M4 M1 M2 M3 B4 B3 F1 F2 F3 F4 B1 B2...

Страница 19: ...supply unit Model AL 320X General Section The electric system power supply unit developed by ArSilicii models AL 320X can control the various sources of energy available on the motor caravan The ener...

Страница 20: ...1 Assembly of a single Panel Make sure the panel is fitted with a non return diode and if not install one If a single panel is fitted it should be connected as shown in Figure 4 In the figure below t...

Страница 21: ...used Case 2 Assembly of two panels The connection is similar to the previous one with the difference that the two panels are put in parallel with the appropriate non return diodes 3 4 2 3 4 1 2 3 4 1...

Страница 22: ...cess the solar panel hierarchy pressing OK and use the right and left arrows to turn ON and OFF respectively S4 S5 S6 Figure 8 Switching the Panel On Off Moving down the hierarchy using the down arrow...

Страница 23: ...stalling solar panels ArSilicii v041113 23 S4 Figure 9 Power indication Moving further down the hierarchy takes you to the current display instead of Power in Figure 9 the current will be shown this t...

Страница 24: ...hich are thus considered as simple feed throughs The two pin connector J4 is usually used for connecting the output control button Outputs The device has a connector unit for the outputs from J5 to J1...

Страница 25: ...MLX5569 02A2 with the contacts arranged as follows also see Figure 10 GND 12V BUS A BUS B 12V BUS A GND BUS B J1 J2 J3 J4 J1 J2 J3 J4 J5 J9 J8 J7 J6 J12 J11 J10 J13 J14 J5 J9 J8 J7 J6 J12 J11 J10 J13...

Страница 26: ...POWER HUB ArSilicii V041113 26 F3 10 A J4 J3 J2 F4 7 A F1 5 A F6 7 A F7 7 A F5 7 A F2 10 A J1 J1 J12 J11 J9 J10 I2 J8 J5 J6 J7 I1 Figure 11 Power Hub logic diagram...

Страница 27: ...usually used to detect the levels of a tank with a discrete sensor with four levels and connector J5 with 4 pins used to detect the overflow signal from two separate tanks Outputs The output is conne...

Страница 28: ...NSA10 ArSilicii Rel V041113 28 2 GND 3 1 4 12V BUSA BUSB J3 CONNET T ORE6 PIN BERG1 BUSA BUSB 12V CONNET T ORE6PIN MXJ 1 5 GND 4 1 6 12V 3 2 GND 4 3 2 1 5 4 6 2 1 3 CONNET T ORE4PIN BERG2 Figure 12 L...

Страница 29: ...CARATTERISTICHE NODO Mod NSA10 ArSilicii Rel V041113 29 J3 J2 J3 J4 J5 J1 F2 3 A I1 F1 3 A I2 Figure 13 Node equivalent logic layout...

Отзывы: