GROUP BYPASS

Instead of bypassing zones individually, your installer may have assigned several zones

together to be bypassed all at one time. An example would be turning off all the interior

zones of the premises allowing movement, while still protecting the perimeter.

Example:  Interior zones 2, 3 and 4 have been assigned as GROUP BYPASS zones.  To

bypass zones 2, 3 and 4 enter the following key sequence:

Figure 5

0

#

3

4

1

2

ACCESS CODE

 Zones 2, 3, and 4 will BYPASS but the other zones will ARM. This is a very easy way

of arming a part of the system all at one time. The display will show ARMED.

INSTANT/DELAY MODE

The system will normally arm in the Delay Mode when leaving the premise.  This will delay

arming, allowing time to exit.  When entering, the alarm will be delayed allowing time to

disarm the system.  The audible warning device will sound during the entrance delay

reminding you to disarm the system.  The Instant Mode is primarily used in residences.

It is used during sleeping hours when an entrance  delay is not wanted.

If the Instant Mode is desired, enter the key sequence as follows:

Figure 8

0

*

#

3

1

2

4

ACCESS CODE

The LCD display will show ARMED INSTANT .

PANEL TEST MODE

Your alarm system and its associated components (intrusion detectors, smoke detec-

tors, etc.) should be tested periodically. You can test these devices yourself using the

panel test mode. While in test mode the keypad beeps continuously  to tell you it is in  test

Содержание EKP1L

Страница 1: ...1 EKP1L LCD KEYPAD Owner s Manual use with AV9000 series Control panels IT IS IMPORTANT FOR YOUR SAFETY TO TEST YOUR SYSTEM AND IT S COMPONENTS REGULARLY P N 64812818 A PDF 10 14 97...

Страница 2: ...y contain information which pertains to your system The material in this publication is for information purposes only and is subject to change without notice SENTROL INC assumes no responsibility for...

Страница 3: ...nnunciation Your keypad has the added convenience of additional access codes These secondary codes are designed to provide access to a maid or other service persons for whom you want to grant entry Ob...

Страница 4: ...display and assume Auto Scrolling is enabled These descriptions may be changed by your installer DISARMING AND SILENCING THE SYSTEM when ARMED light is on To Disarm your system assume Access Code 123...

Страница 5: ...pen will be scrolling through the display Let us assume that the zone 3 FRONT BEDROOM window is open The zone 3 description FRONT BEDROOM will be in the display Entering the Access Code will not arm t...

Страница 6: ...ystem will normally arm in the Delay Mode when leaving the premise This will delay arming allowing time to exit When entering the alarm will be delayed allowing time to disarm the system The audible w...

Страница 7: ...It is important for your safety that you test your system regularly TESTING COMMUNICATOR Check with your installer as to how to test and how often to test the communicator portion of your system Vario...

Страница 8: ...sarmed To select for chime operation enter the following key sequence Figure 10 3 1 2 4 ACCESS CODE 6 If chime operation is not desired simply re enter the key sequence FAULT CONDITION A Fault Conditi...

Страница 9: ...monitoring station Press the 9 key or the 0 key depending on how your system is programmed after your Access Code then press the ENTER The system will disarm and a silent alarm will be transmitted NO...

Страница 10: ..._____________ PARTITIONED MODE Your installer dealer may have assigned specific zone s for you Other users are sharing the same alarm system There is very little interaction between users and arming a...

Страница 11: ...There are times when you may be instructed by the Monitoring Center to use one of these special commands for that purpose The panel can be instructed to call the computer or to answer when the compute...

Страница 12: ...reaches the ground 5 Draw a sketch of the escape route and familiarize everyone in the home with it 6 Select a meeting place outside where everyone is to report 7 Practice the escape plan with everyon...

Страница 13: ...products from the retail purchaser s location If examined equipment is found not to be defective or is not for some other reason within the warranty coverage Sentrol Inc s service time expended will...

Страница 14: ...510 Tate Boulevard Hickory North Carolina 28601 1 800 800 2626 ING BUT NOT LIMITED TO THE IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED NO OTHER PERSON OR ENT...

Отзывы: