background image

© 2014  Arrive Systems, Inc. All Rights Reserved.

6

CAUTION: READ THIS BEFORE OPERATING YOUR UNIT

1. 

To assure the finest performance, please read this manual 

carefully. Keep it in a safe place for future reference.

2.  Install this unit in a well-ventilated, cool, dry, clean place away 

from direct sunlight, heat sources, vibration, dust, moisture, 

and/or cold.

3.  Locate this unit away from other electrical appliances, motors, 

or transformers to avoid humming sounds.

4. 

Do not expose this unit to sudden temperature changes from 

cold or hot, and do not locate this unit on an environment 

with high humidity (i.e. a room with a humidifier) to prevent 

condensation inside this unit, and/or personal injury.

5.  Avoid installing this unit where foreign object may fall onto 

this unit and/or this unit may be exposed to liquid dripping or 

splashing. On the top of this unit, do not place :

•  Other components, as they may cause damage and/or 

discoloration on the surface of this unit.

•  Burning objects (i.e. candles), as they may fall and liquid 

may cause electrical shock to the user and/or damage 

to this unit.

•  Containers with liquid in them, as they may fall and liquid 

may cause electrical shock to the user and/or damage 

to this unit. 

6.  Do not cover this unit with a newspaper, tablecloth, curtain, 

etc. in order not to obstruct heat radiation. If the temperature 

inside this unit rises, it may cause fire, damage to this unit, 

and/or personal injury.

7.  Do not install this unit near mobile phones and/or televisions 

sets to prevent operation failure caused by electromagnetic 

waves and/or magnetism. 

8.  Install this unit in a stable place to prevent a fall and damage 

to this unit. 

9.  Keep your hands dry when connecting or disconnecting the 

cable to prevent an electric shock.

10. Connect USB ports on the device directly to PC. Connecting 

them through a USB hub may cause problems in operations.

11. 

Do not use force in the cable. Doing so may cause a fire, 

electrical shock, damage to this unit, short circuit and/or 

disconnecting.

12. When not planning to use this unit for long periods of time, 

disconnect the cable from the ethernet and/or power sockets 

to prevent fire.

13. When disconnecting any cable, grasp the plug- do not pull the 

cable. 

14. 

Do not clean this unit with chemical solvents; this might 

damage the finish. Use a clean or dry cloth.

15. 

Do not attempt to modify or fix this unit.  Contact qualified 

ARRIVE service personnel when any service is needed.

16. Condensation will form when any surrounding temperature 

changes suddenly. Disconnect the cables, then leave this unit 

alone.

17. When using this unit for a long time, this unit may become 

warm. Disconnect the cables, then leave this unit alone for 

cooling.

18. 

To prevent damage by lightning, keep the cables disconnected 

during a lightning storm.

WARNING 

 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT 

EXPOSE THIS UNIT TO RAIN OR MOISTURE.

 

WARNING 

 

TO PREVENT ELECTRIC SHOCK, ENSURE THAT YOU ARE 

USING MATCHING  POWER PLUGS TO THE POWER SOCKET 

AND FULLY INSERT.

 Information for users on collection and disposal of old 

equipment

This symbol on the products, 

packaging, and/or accompanying 

documents means that used 

electrical and electronic products 

should not be mixed with general 

household waste. 

For proper treatment, recovery and 

recycling of old products, please 

take them to applicable collection 

points, in accordance with your 

national legislation and Directives 

2002/96/EC.

By disposing of these products correctly, you will help to 

save valuable resources and prevent any potential negative 

effects on human health and the environment which could 

otherwise arise from inappropriate waste handling.

For more information about collection and recycling of old 

products, please contact your local municipality, your waste 

disposal service or the point of sale where you purchased 

the items.

[For business users in the European Union] 

 

If you wish to discard electrical and electronic equipment, 

please contact your dealer or supplier for further 

information.

[Information on Disposal in other Countries outside the 

European Union]

 

This symbol is only valid in European Union, If you wish to 

discard these items, please contact your local authorities or 

dealer and ask for the correct methods of disposal. 

 

 

Содержание EyePoint AEP-3028

Страница 1: ... 3028 Please note the serial number of your purchased product for future reference Model No _________________ Serial No ___________________________________________ USER MANUAL AEP 3028 804 001 AEP 3028 UPTW USB 3 0 HD CAMERA ...

Страница 2: ... Arrive Systems Inc All Rights Reserved 2 We reserve the right to introduce changes after the printing of this document Please refer to our website www arrivesys com for updated documentation and information ...

Страница 3: ... 2014 Arrive Systems Inc All Rights Reserved 3 CONTENTS 1 INTRODUCTION 9 2 FEATURES AND SPECIFICATIONS 9 3 INSTALLING THE DEVICE 12 4 USING THE DEVICE 15 5 CONNECTING THE CAMERA 21 6 TROUBLESHOOTING 25 ...

Страница 4: ... not likely to be walked on or pinched by items placed upon or against them paying particular attention to cords at plugs convenience receptacles and the point where they exit from the product 12 Lightning For added protection for this product during a lightning storm or when it is left unattended and unused for long periods of time unplug it from the ethernet and or from the power socket This wil...

Страница 5: ... A digital devices Compliance with these requirements provides a reasonable level assurance that your use of this product in a residential environment will not result in harmful interference with other electronic devices This equipment generates uses radio frequencies and if not installed and used according to the instructions found in the user manual may cause interference harmful to the operatio...

Страница 6: ...ng to use this unit for long periods of time disconnect the cable from the ethernet and or power sockets to prevent fire 13 When disconnecting any cable grasp the plug do not pull the cable 14 Do not clean this unit with chemical solvents this might damage the finish Use a clean or dry cloth 15 Do not attempt to modify or fix this unit Contact qualified ARRIVE service personnel when any service is...

Страница 7: ...UT OF THE USE OR INABILITY TO USE THIS MANUAL EVEN IF ARRIVE OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES ALL TRADEMARKS AND INFORMATION ARE OWNED BY THE RESPECTIVE OWNERS OF THE TRADEMARKS AND INFORMATION WHETHER ACKNOWLEDGED OR NOT IN THIS MANUAL ARRIVE DOES NOT CLAIM ANY OWNERSHIP OF ANY TRADEMARK OR TRADENAME MENTIONED IN THE INFORMATION EXCEPT FOR THE ARRIVE TRADENAME...

Страница 8: ...28 UPTW this unit device About Trademarks All other trademarks are owned by their respective owners whether acknowledged or not in this manual Specifications of this unit and contents of this document are subject to change without notice ARRIVE does not accept any liability for any loss or damage resulting from any use of this unit the warranty covers this unit only ...

Страница 9: ...028 UPTW comes from the family of USB 3 0 super speed HD cameras from Arrive It offers unparalleled clarity and resolution for a host of applications irrespective of room sizes and light conditions They are ideal solutions for video conferencing distance learning training meeting courtroom and any other application that involves high quality color video cameras with the flexibility of remote opera...

Страница 10: ...R remote controller signal VISCA IN RS232 VISCA OUT RS485 Control Interface Accomodates daisy chain connection of multiple cameras When multiple cameras are connected to PC via RS 232C VISCA IN connect VISCA OUT of the first camera to VISCA IN of the second camera DC12V 1 2A Power supply socket Physical specifications Figure 3 Arrive EyePoint front and side dimensions ...

Страница 11: ...ns Image Sensor Sensor 1 2 8 CMOS 2 0 Mega Pixel Minimum illumination 0 5Lux at F2 0 White Balance AUTO Manual Gain Control AUTO Back light compensation ON OFF S N Ratio 50db Lens Focus AUTO Iris AUTO Manual Lens 4 0mm F1 6 Fixed lens Horizontal View 70 degrees Video Output USB 3 0 UY2 Video format YUY2 1080P 60 1080P 30 1080P 25 1080P 24 1080i 60 1080i 50 720P 60 720P 50 Control Decoder EIA RS 48...

Страница 12: ...5 degree Auto Pan Scan Supported Boundary Scan 0 359degrees Programable Remoter Control IR Wireless remote control P T Z Power DC12V 10 1 2A Operation Temperature 10oC 60oC Environmental humidity 0 95 RH non condensaion Length X width X height 124x120x145mm NET 220x175x220mm PACKAGE Weight 640g 1100g NET PACKAGE Mounting Desktop Ceiling Wall mount Standard Tripod 3 INSTALLING THE DEVICE Package co...

Страница 13: ...Rights Reserved 13 Bracket installation STEP 1 STEP 2 STEP 3 STEP 4 Figure 4 Bracket Installation After the bracket is fixed to the camera base the camera can be installed on the ceiling wall or any flat surface as per requirement ...

Страница 14: ... 2014 Arrive Systems Inc All Rights Reserved 14 Tripod installation Fix the tripod accessory to the bottom of the Arrive EyePoint and mount the camera on the tripod Figure 5 Tripod Installation ...

Страница 15: ...en the OSD menu is ON the Pan Tilt of the camera cannot be adjusted Self Testing OSD Menu This menu is displayed with Camera Power on and disappears after self testing completed Menu Item Meaning Value Address Camera address 1 Baud Rate Camera baud rate 9600 Protocol PTZ Control Protocol VISCA Control Camera control type RS 232C Lens Type Camera module adopted Acute Sony Dome Type Camera model No ...

Страница 16: ...ange 1 63 30 Tilt Speed Adjustable tilt movement speed Range 1 63 30 Scan Speed Adjustable pan movement speed Range 1 63 6 Tour Path Optional tour path Range 1 4 1 Tour Dwell Tour duration time Range 1 60 5 Proportion Enable disable speed match function Possible values ON OFF ON Auto Rev Image auto flip Vlaues P positive N inverted OFF P Frame Format 1080p 30 1080p 25 1080p 24 1080i 60 1080i 50 72...

Страница 17: ...ode Manual PAE AAE SAE PAE Aperture mode F1 8 F11 F1 8 Shutter speed Shutter speed range 1 5 1 4000 1 5 Ev correction 2 1 66 1 33 1 0 66 0 33 0 0 33 0 66 1 1 33 1 66 2 0 ISO sensitivity Auto Manual Auto Manual setup ISO80 ISO100 ISO200 ISO400 ISO800 ISO1000 IS080 Flicker reduction ON OFF ON White balance Auto Custom Manual Daylight Cloudy Shade FLW FLN FLD Tungsten Auto Digital effect Normal Sepia...

Страница 18: ... 2014 Arrive Systems Inc All Rights Reserved 18 Device Remote Control Figure 6 Remote control 1 2 3 4 5 6 7 8 9 10 11 ...

Страница 19: ...Choose the preset position Set Set the preset position 4 Zoom Fast Zoom Fast Increase the Zoom In speed Increase Zoom Out speed 5 Pan Tilt control Move camera upwards Move camera downwards Move camera left Move camera right Enable Pan movement scanning 6 Auxiliary Freeze Image Freeze BL Backlight compensation WB White Balance AE Auto Exposure DZOOM Digital Zoom HDMI N A DVI N A Format N A ...

Страница 20: ...peed Reduce Zoom out speed 10 Lens Focus Auto Auto focus Manual Manual focus Far Far end lens zoom Near Near end lens zoom 11 Pan Tilt Function area L Limit Set left limit points for boundary scanning Scan Enable scanning automatically R Limit Set right limit point for boundary scanning Home Home position of camera Tour Enable touring Rev Image up side down option ...

Страница 21: ...VISCA RS 232C IN Reference 1 2 3 5 6 7 8 VISCA RS 232C IN Figure 7 VISCA RS 232 C IN Pin S N Function 1 DTR IN 2 DSR IN 3 TXD IN 4 GND 5 RXD IN 6 GND 7 IR Commander Signal OUTPUT 8 NO Connection VISCA Out Reference 1 2 3 5 6 7 8 VISCA RS 232C OUT Figure 8 VISCA RS 232C OUT ...

Страница 22: ... 8 RS 485 Pin Configuration for Connecting Camera to PC Camera Computer 9 Pin 1 DTR IN 1 CD 2 DSR IN 2 RXD 3 TXD IN 3 TXD 4 GND 4 DTR 5 RXD IN 5 GND 6 GND 6 DSR 7 IR OUT 7 RTS 8 N C 8 CTS 9 RI Camera Computer 25 Pin 1 DTR IN 1 FG 2 DSR IN 2 TXD 3 TXD IN 3 RXD 4 GND 4 RTS 5 RXD IN 5 CTS 6 GND 6 DSR 7 IR OUT 7 GND 8 N C 20 DTR ...

Страница 23: ... 1 DTR OUT 1 DTR IN 2 DSR OUT 2 DSR IN 3 TXD OUT 3 TXD IN 4 GND 4 GND 5 RXD OUT 5 RXD IN 6 GND 6 GND 7 RS485 7 IR OUT 8 RS485 20 N C References Note Switch off the power supply prior to altering the DIP switch settings DIP switch settings ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 8 7 SW1 SW2 底部拨码开关视图 Figure 9 DIP switch overview ...

Страница 24: ... ON OFF OFF 6 OFF OFF OFF OFF OFF ON OFF 7 OFF OFF OFF OFF OFF OFF ON Firmware upgrading Firmware software upgrade Set SW1 DIP 8 to ON Normal Work Mode Set SW1 DIP 8 to OFF Baud rate communication protocol assignment Baud rate SW 2 DIP 1 Communication SW 2 DIP 2 Protocol SW 2 DIP 3 38400bps ON RS 485 ON PELCO D ON 9600bps OFF RS 232 OFF VISCA OFF IR Remote control Input settings R C Address SW 2 D...

Страница 25: ...re setting Check the connection between video cable camera and monitor fix the connector on each end Check and rectify the exposure settings Unable to Pan Tilt and Zoom camera OSD Menu is active Pan and tilt range is limited Exit the OSD Menu and then re operate Remote control is not working Mismatch between the camera select on the remote and IR select switch number Choose the right IR select num...

Страница 26: ...www arrivesys com Arrive Systems Inc 6737 Katella Ave Cypress CA 90630 USA Toll Free 1 844 427 7483 USA Canada Email info arrivesys com 2014 Arrive Systems Inc All Rights Reserved ...

Отзывы: