background image

Dimensions

8

SkyPanel S120-C (P.O. version)

Содержание SkyPanel S120-C

Страница 1: ...User Manual October 2016 ...

Страница 2: ...Ltd L5 0006983 Rev L02908 2015 2016 Arnold Richter Cine Technik GmbH Co Betriebs KG ARRI All rights reserved Information subject to change without notice ARRI and all affiliated companies disclaim liability for any injury damage direct or indirect loss con sequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this docume...

Страница 3: ...Dimensions 3 Dimensions SkyPanel S30 manual version ...

Страница 4: ...Dimensions 4 SkyPanel S30 P O version ...

Страница 5: ...Dimensions 5 SkyPanel S60 manual version ...

Страница 6: ...Dimensions 6 SkyPanel S60 P O version ...

Страница 7: ...Dimensions 7 SkyPanel S120 C manual version ...

Страница 8: ...Dimensions 8 SkyPanel S120 C P O version ...

Страница 9: ...oduction 15 Features 15 Properties 16 Unpacking 16 Overview 17 Physical Installation 21 To Mount the Stirrup And the Spigot 21 Basic Features 24 Control Options 25 To Power the SkyPanel 26 AC Power 26 To Use a Battery Pack 27 Fixture Menu 29 Overview 29 Features of the Fixture Menu 29 Fixture Control 39 Art Net 40 DMX 41 Fixture Menu 42 RDM commands 47 ...

Страница 10: ...Content 10 Error Codes 51 ARRI Lighting Service Manager 52 Protocol 53 Specification 72 ...

Страница 11: ...ns important instructions and notes to handle the product safe Always follow all safety information for your own protection Please contact a trained ARRI service technician to do any service and maintenance not described in this manual Please follow the user manual of accessories and third party accessories such as battery packs and battery chargers They contain important safety and security infor...

Страница 12: ...repair work is only to be carried out by an authorized ARRI service center Do not operate the product if the ambient tempera ture exceeds 45 C Observe all information given in chapter Specification on page 72 Do not expose the product to rain or moisture Do not use the product for 2 h when it was exposed to big temperature differences as condensed moisture may damage the product electrically when ...

Страница 13: ...mounted hanging or standing vertically Lateral load can cause deformation or breaking of the spigot and the stirrup Devices and accessories must be secured against fall when mounted above floor level Always observe common and local safety regulations Never use the cables for transportation Never hang the product on its cables Do not hang a battery pack on its connection cable to the product Always...

Страница 14: ...lease contact the manufacturer or his service agent or a similar qualified person Firmware Downgrade Note Please observe that it is not possible to downgrade the firmware to a version lower 1 0 0 after updating to version 1 0 0 or higher Maintenance Information Do not clean the surface of the product with solvents or strong detergents Clean the product with a soft cloth wetted with a mild deter ge...

Страница 15: ... digital cameras All models of the SkyPanel can be controlled using the common DMX512 A protocol the Art Net protocol or the fixture menu The SkyPanel is powered by AC power or a battery pack Please find more detailed information in section To Power the SkyPanel on page 26 Features Light Field The SkyPanel offers the same functionality as a conventional softlight Even Light Field The SkyPanel soft...

Страница 16: ... DMX or Art Net The SkyPanel is also fully RDM compatible both via DMX and Art Net with suitable controllers and is equipped with a feedback channel for reporting all set parameters including system status Fixture Menu For location applications the SkyPanel is equipped with a fixture menu for manual adjustment of intensity color tempera ture and plus minus green as well as hue and saturation de pe...

Страница 17: ...verview Manual Version Diffusor or remote phosphor panel Top latches Stirrup Handle Tilt lock Tilt lock lever Fixture menu Connector panel Spigot Figure 1 Front and back view manual version the figure shows the S60 ...

Страница 18: ... O Version Diffusor or remote phosphor panel Top latches Stirrup Handle P O drives Fixture menu Connector panel Spigot Figure 5 Power supply unit S30 Figure 2 Front and back view P O version the figure shows the S30 ...

Страница 19: ...Overview 19 USB A Ethernet DMX DMX connector Thru In port Power in 48 V Battery in 23 36 V Boot mode Figure 3 Connector panel ...

Страница 20: ...upply Unit S60 S120 Power Supply Unit S30 Power in and thru Power out 48 V Main switch Figure 4 Power supply unit S60 S120 Power out 48 V Main switch Front panel Power in and thru Back panel Figure 5 Power supply unit S30 ...

Страница 21: ...ted hanging or standing vertically Lateral load can cause deforma tion or breaking of the spigot and the stirrup CAUTION Block access below the work area and work from a stable platform whenever installing ser vicing or moving the product or accessories IMPORTANT Do not illuminate the display and the diffuser plate by high power light beams from a short distance The display and the light engine ar...

Страница 22: ...onjunction the Center mount yoke L2 0008078 and Fixed center mount yoke L2 0008080 The brackets are in tended to be used as an anchor point for a safety cable To Dismantle the Stirrup Place the SkyPanel with the lighting aperture facing down wards on an even and clean surface Loosen and remove two allen screws on each side of the product 4 mm allen key see Figure 6 Remove the stirrup To Mount the ...

Страница 23: ...nd accessories Keep care that Both guiding rails are locked Tripods are set up in a stable position Tripods need to be ap proved for the load they need to carry Always observe the additional load of cables and accessories Top latch locked Top latch unlocked Figure 8 Locking top latches Figure 7 To mount the safety loop brackets ...

Страница 24: ...mpletely into the guiding rails Close the cover strip Lock both top latches by sliding both levers completely outwards see Figure 8 To Mount a Barndoor A barndoor is mounted using the outer guiding rails see Figure 9 To mount a barndoor on the S30 and S60 Close the cover strip Lock both top latches by sliding both le vers completely outwards see Figure 8 Insert the barndoor completely into the out...

Страница 25: ...trol via Art Net uploading firmware and setting parameters The Ethernet port can be used for service purpose like downloading error re ports from the product and set certain data To do so you need a software tool the ARRI Lighting Service Manager ALSM and an RJ45 network cable to connect your PC with the SkyPanel Download the ALSM free of charge from the ARRI web site www arri com lightingsoftware...

Страница 26: ...by an external power supply unit PSU The PSU is an auto sensing switch mode power supply that automatically adapts to AC power at 100 240 V 50 60 Hz nom Make sure that no person stares at the light output aperture and the product is isolated from DMX before you connect it to a power supply unit or a battery pack You can hard wire the SkyPanel to a building electrical instal lation You can install ...

Страница 27: ...rce in the power in socket until it locks Line up the raised key of the male cable connector and the keyway of the power out socket of the power supply unit In sert the cable connector without force in the power out socket until it locks To remove the cable connectors Press the connector lock and pull the cable connector out of the socket Power Through The external power supply is equipped with a ...

Страница 28: ...s 45 V To Insert and Remove the 4 pin XLR Cable Connector To insert the 4 pin XLR cable connector The main switch of the battery pack must be turned off if possible Align the raised key of the cable connector with the keyway of the input socket see Figure 3 on page 19 Insert the cable connector without force in the input socket The cable connector must lock Repair or replace cable con nectors that...

Страница 29: ...ter mode active White Receiving valid Art Net signal Gateway active Green Receiving valid Art Net signal Gateway not active Red No communication between fixture menu and controller board No light The fixture receives no valid control signal Color Indication Green No error Normal temperature Red flashing 0 5s rhythm Warning fixture over tempera ture only with fan modes LOW and High Speed Red Fixtur...

Страница 30: ... dialog opens Turn I S 4 to select a preset memory slot Press I S 4 to store the preset Close the dialog with BACK MODE 8 MODE swaps between CCT HSI and GEL mode only Sky Panel C Press the MODE long to open Light Mode DISPLAY 9 The display shows the current settings and other information during normal operation Press the MENU button 4 to open or close the fixture menu Use I S 4 and the BACK button...

Страница 31: ...options Best color displays the gel with optimized color quality Brightest displays the gel with optimized brightness Press I S 4 to open the gel library Choose the gel manufac turer Rosco or LEE with the central rotary knob 5 Use the right rotary knob 6 to activate a gel category as shown in the table below Turn I S 4 to call up a gel from the gel set Press BACK 11 to close the gel set and set th...

Страница 32: ... affect both the intensity control via the fixture menu or DMX and Art Net Low End Mode The Low End Mode optimizes the dimmer quality at low intensity levels and enables SkyPanel to gener ate accurate CCTs with high color rendition and smooth dim ming at very low light levels The Low End Mode can cause flickering when used with cameras shooting at high frame rates Tungsten Mode The tungsten Mode c...

Страница 33: ... master fixture Press MENU to close the menu All fixtures in the data link will mimic the master fixture automat ically and independent from their settings Please note when using the master slave mode Art Net is de activated on all fixtures in the data link Changing the mode on the master fixture CCT HSI GEL changes the mode on all slave fixtures accordingly The settings DMX protocol version DMX a...

Страница 34: ...ixture menu Turn I S until Fan Mode is displayed Press I S to open the menu Select the Fan mode by turning I S Press I S to confirm the setting The menu Fan Mode closes automatically Press the MENU button to force closing the menu Option Description Hold Last Command The last received DMX values are used until the fixture is switched off or valid DMX data is received again Blackout The fixtures do...

Страница 35: ...layed Press I S to open the menu Select the desired brightness by turning I S Press I S to confirm the setting Turn I S until Display Contrast is displayed Press I S to open the menu Select the desired contrast by turning I S Press I S to confirm the setting Turn I S until Display Rotation is displayed Press I S to open the menu Select the desired setting by turning I S Press I S to confirm the se...

Страница 36: ... memory stick Be sure to keep the string when renaming a pre set list Otherwise the file will not be found by the SkyPanel To load a preset list Connect an USB memory stick with one or more preset lists to the USB A connector of the SkyPanel Press the MENU button 10 to open the fixture menu Turn I S until USB Functions is selected Press I S to open the menu Turn I S until Load Light Presets is sel...

Страница 37: ...B memory stick Turn I S to select a fixture settings file Press I S to load the selected fixture settings The SkyPanel restarts with the new fixture settings after successful upload To Save the Error and Service log For diagnosis purpose you might be asked to send the error and service log to the ARRI service The log files can be down loaded to an USB memory stick The file name contains the date t...

Страница 38: ...ss the MENU button 10 to open the fixture menu Turn I S until Factory Reset is displayed Press I S to open the menu Turn I S to choose the option Yes and perform a factory re set Press BACK 11 to abort The SkyPanel reboots with its factory settings ...

Страница 39: ...HSI only SkyPanel C Provides control of intensity color temperature green hue and saturation HSI hue saturation intensity In HSI mode the color and intensity is very even over the fixtures as it is con trolled using color algorithms which take the tolerances of the light engines into account during calculation RGBW only SkyPanel C Simple mode for controlling the overall intensity and the red green...

Страница 40: ...Nets or 256 consecutive Uni verses is referred to as a net There are 128 Nets in total Sub Net A group of 16 consecutive universes is referred to as a sub net Not to be confused with the subnet mask Universe A single DMX512 frame of 512 channels is referred to as a Universe Art Net Merge Mode The Art Net protocol allows multiple nodes or controllers to transmit ArtDmx data to the same universe Mer...

Страница 41: ...Panels individual you need to set up additional DMX data links Tips for a Reliable Data Transmission Use shielded twisted pair cable designed for RS 485 devices or CAT 6 network cables Standard microphone cable cannot transmit control data reliably over long runs 24 AWG cable is suitable for runs up to 300 meters 1000 ft Heavier gauge cable and or an amplifier is recommended for longer runs To spl...

Страница 42: ...re holds the last received control values Black Out Fixture douses the dimmer Hold 2 Min Fade Out Hold the last received values for 2 min then douse DMX Protocol Version Version 4 2 Version of the DMX protocol Version 4 1 Version 4 0 Version 3 4 Fan Mode Low Fan Speed Low fan speed silent operation Vari Fan Speed Temperature regulated fan speed High Fan Speed High fan speed best cooling Light Mode...

Страница 43: ...Modes Low End Mode Off Flicker free light On Optimized dimming behavior at low intensity levels Tungsten Mode Off Color temperature optimized when dimming On Emulates the behavior of a tungsten light Master Slave Mode Off Master Slave Mode OFF On Master Slave Mode active Lighting Effects Off No stand alone effect Party Effect Stand alone effect see page 35 Level 1 Level 2 Level 3 Level 4 Explanati...

Страница 44: ...red Hidden Show error codes Status LEDs and display illumina tion off USB Functions Light Presets Save Light Presets No Store preset list to an USB memory stick see page 36 Yes Load Light Presets List Load preset list from an USB memory stick Select pre set list with Intensity Selector see page 36 Fixture Settings Save Fix Settings No Store fixture settings to an USB memory stick see page 36 Yes L...

Страница 45: ...nu Fixture Settings Fixture Info Fixture Status System Ready No error Error Message Error message see page 51 Light Engine Temp xx x C xx x F Recent light engine temperature Hour Counter xxh Light Engine yyh System Working hours of the light engines and of the system since production of the fixture Battery Status x y V Recent voltage of an external battery MAC Address u v w x y z The fixtures MAC ...

Страница 46: ...IP address assigned via DHCP if active If manual mode is active AAA 10 172 or 192 BBB 0 255 16 31 or 168 CCC 0 255 DDD 0 255 If changed the IP mode is automatically set to Man ual Display Version x xx xx xxxx The displays firmware version USB Mode Normal USB port powered Service USB port not powered Do not change this setting unless being asked by ARRI service Risk of dam age Factory Reset No Abor...

Страница 47: ... not standard rdm commands mostly commands from manufacturer Describes the data type and shows if Set or Get or both are sup ported for the listed commands X Device Info Lists RDM protocol version device model ID product category software version ID from Main DMX footprint DMX personality sub device count and sender count X Software Version Label Shows the software version string from main e g Mai...

Страница 48: ... Manufacturer Label Display the company name ARRI Lighting X Boot Software Version ID PrBo SW Version e g 2 03 00 X Boot Software Version Label Shows text from PrBo Bootloader e g PrBo 2 03 00 Jan 16 2012 19 10 26 X DMX Personality DMX mode X X DMX Personality Description Displays a text description of a DMX mode with up to 32 characters shown exactly as in the description in the ALSM X Slot Info ...

Страница 49: ..._FULL_OFF 0x00 POWER_STATE_SHUTDOWN 0x01 X X Perform Selftest Supported test modes and demo modes X X Self Test Description Shows a description for each test demo mode X Command Description GET SET RDM Fan Mode PID 0x8001 Changes the FAN mode of the fixture this message supports Set and Get commands the first data byte is used to show change the fan mode USER_FAN_MODE_LOW 1 USER_FAN_MODE_VARI 2 US...

Страница 50: ...If the DMX signal gets lost or the DMX device is unplugged the LED fixture holds the last valid signal or it holds the last valid signal for two minutes and then douses or switches off immediately Supported values 0 hold 1 hold 2 minutes 3 switch off X X Command Description GET SET ...

Страница 51: ...un at all Set the fan to LOW or High Speed and see if it starts rotating in order to determine if there is an electrical malfunction All mechanical tests or repairs may only be carried out by a trained service technician E 011 Fixture menu module not be detected If the fixture menu is working error E 011 can be ignored However if the fixture menu remains dark no LED lights up we recommend to conta...

Страница 52: ...in If the problem persists please contact the ARRI service E 019 Diffuser removed The diffusor was removed The protection circuit is active only RP version E 020 Update with errors This will be seen if the update process has detected an error during the update Please look at the error log for more information to see which model or component had a problem with the update E 021 Flash init error No f...

Страница 53: ...255 0 100 Master Intensity 0 100 open 2 Reverts to fixture set ting when signal lost 0 9 10 60 61 120 121 180 181 250 251 255 0 4 5 23 24 47 48 70 71 98 99 100 Fan Control No function Low Variable High Fan max speed Fan off 3 5 Reserved only V4 x Channel Value Percent Function 1 HI 0 65 535 0 100 Master Intensity 0 100 open 2 LO 3 Reverts to fixture set ting when signal lost 0 9 10 60 61 120 121 1...

Страница 54: ... Green 3313 1 2 Green 3315 1 4 Green 3314 1 4 Green 3316 1 8 Green 3318 1 8 Green 3317 Channel Value Percent Function 1 0 255 0 100 Master Intensity 0 100 open 2 0 255 0 100 Color temperature CCT 2 800 K 10 000 K 3 0 10 11 20 21 119 120 145 146 244 245 255 0 4 5 8 8 46 47 57 57 96 96 100 GN saturation neutral no effect full minus green 99 1 neutral no effect 1 99 full plus green 4 0 255 0 100 Xfad...

Страница 55: ...99 100 Fan Control No function Low Variable High Fan max speed Fan off 5 7 Reserved only V4 x Channel Value Percent Function 1 0 255 0 100 Master Intensity 0 100 open 2 0 255 0 100 Color temperature CCT 2 800 K 10 000 K 3 0 10 11 20 21 119 120 145 146 244 245 255 0 4 5 8 8 46 47 57 57 96 96 100 GN saturation neutral no effect full minus green 99 1 neutral no effect 1 99 full plus green 4 0 255 0 1...

Страница 56: ...81 250 251 255 0 4 5 23 24 47 48 70 71 98 99 100 Fan Control No function Low Variable High Fan max speed Fan off 7 9 Reserved only V4 x Channel Value Percent Function 1 0 255 0 100 Master Intensity 0 100 open 2 0 255 0 100 Hue 0 360 3 0 255 0 100 Saturation 0 full saturated 4 Reverts to fixture set ting when signal lost 0 9 10 60 61 120 121 180 181 250 251 255 0 4 5 23 24 47 48 70 71 98 99 100 Fan...

Страница 57: ...0 9 10 60 61 120 121 180 181 250 251 255 0 4 5 23 24 47 48 70 71 98 99 100 Fan Control No function Low Variable High Fan max speed Fan off 18 20 Reserved only V4 x Channel Value Percent Function Channel Value Percent Function 1 HI 0 65 535 0 100 Master Intensity 0 100 open 2 LO 3 HI 0 65 535 0 100 Color temperature CCT 2 800 K 10 000 K 4 LO 5 HI 0 5 000 5 001 10 000 10 001 29 999 30 000 40 000 40 ...

Страница 58: ...0 LO 11 HI 0 65 535 0 100 Saturation 0 full saturated 12 LO 13 Reverts to fixture set ting when signal lost 0 9 10 60 61 120 121 180 181 250 251 255 0 4 5 23 24 47 48 70 71 98 99 100 Fan Control No function Low Variable High Fan max speed Fan off 14 16 Reserved only V4 x Channel Value Percent Function 1 HI 0 65 535 0 100 Master Intensity 0 100 open 2 LO 3 HI 0 65 535 0 100 Intensity red 0 100 4 LO...

Страница 59: ...lor temperature CCT coarse 2 800 K 10 000 K 4 0 255 0 100 Color temperature CCT fine 5 0 10 11 20 21 119 120 145 146 244 245 255 0 4 5 8 8 46 47 57 57 96 96 100 GN saturation neutral no effect full minus green 99 1 neutral no effect 1 99 full plus green 6 0 255 0 100 Xfade to color white RGBW color 7 0 255 0 100 Intensity red coarse 0 100 8 0 255 0 100 Red fine 9 0 255 0 100 Intensity green coarse...

Страница 60: ...7 9 Reserved only V4 x Channel Value Percent Function 1 0 255 0 100 Master Intensity coarse 0 100 open 2 0 255 0 100 Master Intensity fine Channel Value Percent Function 3 0 255 0 100 Color temperature CCT coarse 2 800 K 10 000 K 4 0 255 0 100 Color temperature fine 5 0 10 11 20 21 119 120 145 146 244 245 255 0 4 5 8 8 46 47 57 57 96 96 100 GN saturation neutral no effect full minus green 99 1 neu...

Страница 61: ... 11 Reverts to fixture set ting when signal lost 0 9 10 60 61 120 121 180 181 250 251 255 0 4 5 23 24 47 48 70 71 98 99 100 Fan Control No function Low Variable High Fan max speed Fan off 12 14 Reserved only V4 x Channel Value Percent Function 1 0 255 0 100 Master Intensity coarse 0 100 open 2 0 255 0 100 Master Intensity fine 3 0 255 0 100 Hue coarse 0 360 4 0 255 0 100 Hue fine 5 0 255 0 100 Sat...

Страница 62: ...T max CCT min 100 Channel Value Percent Function 1 0 255 0 100 Master Intensity 0 100 open 2 0 128 129 255 0 50 51 100 Gel 1 CCT Selection 3 200 K 5 600 K 3 0 128 129 170 171 255 0 50 51 67 68 100 Gel 1 Color Matching Best Color Color quality optimized Brightest Color brightness opt No Color Gel 4 0 128 129 255 0 50 51 100 Gel 1 Brand Category on ch 5 Gel on ch 6 Rosco LEE Filters 5 0 50 51 101 10...

Страница 63: ...ry 1 Rosco Color Correction LEE Color Correction Category 2 Rosco CalColor LEE Color Filters Category 3 Rosco Storaro Selection LEE 600 Series Category 4 Rosco Cinelux LEE Cosmetic Filters Category 5 LEE 700 Series Channel Value Percent Function 12 0 255 0 100 Gel 2 See tables below 13 0 51 52 102 103 153 154 204 205 255 0 20 21 40 41 60 61 79 80 100 Gel Transition Type Direct Through White Point ...

Страница 64: ...osco Storaro Selection LEE 600 Series Category 4 Rosco Cinelux LEE Cosmetic Filters Category 5 LEE 700 Series 7 0 255 0 100 Gel 1 See tables below 8 HI 0 65 535 0 100 Xfade to Gel Gel 1 Gel 2 9 LO 10 0 128 129 255 0 50 51 100 Gel 2 CCT Selection 3 200 K 5 600 K 11 0 128 129 170 171 255 0 50 51 67 68 100 Gel 2 Color Matching Best Color Color quality optimized Brightest Color brightness opt No Color...

Страница 65: ...5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 Full CTB 3 4 CTB 1 2 CTB 1 3 CTB 1 4 CTB 1 8 CTB Double CTB Full CTO 3 4 CTO 1 2 CTO 1 4 CTO 3202 3203 3204 3206 3208 3216 3220 3407 3411 3408 3409 Channel Value Percent Function Chan Value Gel name Number 6 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 255 1 8 CTO...

Страница 66: ...ender 30 Lavender 60 Lavender 90 Lavender Reserved 4215 4230 4260 4290 4307 4315 4330 4360 4390 4415 4430 4460 4490 4515 4530 4560 4590 4615 4630 4660 4690 4715 4730 4760 4790 4815 4830 4860 4890 4915 4930 4960 4990 Chan Value Gel name Number 6 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 255 VS Red VS Orange VS Yellow VS Green VS Cyan VS Azure VS Blue VS Indigo VS Violet VS Magenta Reserv...

Страница 67: ...42 44 47 51 60 360 62 362 364 65 365 375 376 77 378 80 381 83 87 88 89 91 92 93 99 Chan Value Gel name Number 6 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 Double CTB Full CTB 3 4 CTB 1 2 CTB 1 4 CTB 1 8 CTB Double CTO Full CTO 3 4 CTO 1 2 CTO 1 4 CT...

Страница 68: ...er Lavender Lavender 002 003 004 007 008 009 010 013 017 019 020 021 022 024 025 026 035 036 046 048 052 053 058 Chan Value Gel name Number 6 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 Mist Blue Pale Blue Sky Blue Eve...

Страница 69: ...e Blue Alice Blue Palace Blue Regal Blue Reserved 138 140 142 143 144 147 148 151 152 153 154 156 157 159 161 162 164 165 169 170 174 176 180 182 192 194 195 196 197 198 199 Chan Value Gel name Number 6 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 255 Arctic White Silver Platinum Moonlight White Full CT 85 Industry Sodium HI Sodium Urban Sodium LO Sodium Reserved 600 601 602 603 604 650 651 652 ...

Страница 70: ... Blue Mikkel Blue Colour Wash Blue Berry Blue Virgin Blue Ocean Blue Old Steel Blue Steel Green Liberty Green Dirty Ice Damp Squib JAS Green am Brown Dirty White Brown 700 701 702 703 704 706 708 709 710 711 712 714 715 716 719 721 723 724 725 728 730 731 733 738 742 744 746 Chan Value Gel name Number 6 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 255 Easy...

Страница 71: ...55 0 4 5 23 24 47 48 70 71 98 99 100 Fan Control No function Low Variable High Fan max speed Fan off 9 11 Reserved only V4 x Channel Value Percent Function 1 HI 0 65 535 0 100 Master Intensity 0 100 open 2 LO 3 HI 0 65 535 0 100 X1 Coordinate 0 0 0 8 4 LO 5 HI 0 65 535 0 100 Y1 Coordinate 0 0 0 8 6 LO 7 HI 0 65 535 0 100 Xfade X1 Y1 X2 Y2 8 LO 9 HI 0 65 535 0 100 X2 Coordinate 0 0 0 8 10 LO 11 HI ...

Страница 72: ... 7 kg 8 2 lbs S60 S120 Light source Type ARRI LED Light Engine Typ LED lifetime L70 50 000 h White light 2 800 K 10 000 K SkyPanel C White light Color temperature defined by remote phosphor panels SkyPanel RP Colored light RGBW color mixing SkyPanel C Color rendition index typ CRI 94 Green Magenta saturation 1 full green to full magenta SkyPanel C Optical path Type soft light with diffuser plate S...

Страница 73: ...PSU and luminaire 15 m 49 ft External power supply unit Power input 100 240 V 50 60 Hz nom Power output 48 V Power supply Auto sensing switching mode power supply Typical power 230 V 50 Hz 200 W SkyPanel S30 400 W SkyPanel S60 400 W SkyPanel S120 cos 0 9 Measurements made at nominal voltage with all LEDs at full intensity Allow for a deviation of 10 Noise emission Ambient temperature 35 C 95 F 20d...

Страница 74: ...ver 3 200 K bare ends Set L0 0007721 S30 RP P O black 3 200 K bare ends Set L0 0007722 S30 RP MAN blue silver 5 600 K Edison Set L0 0007723 S30 RP MAN blue silver 5 600 K Schuko Set L0 0007724 S30 RP MAN blue silver 5 600 K China Set L0 0007725 S30 RP MAN blue silver 5 600 K PSE Japan Set L0 0012396 S30 RP P O blue silver 5 600 K bare ends Set L0 0007726 S30 RP P O black 5 600 K bare ends Set L0 0...

Страница 75: ...C cable 48 V XLR 3 pol l 10 m L2 0007494 DC cable 48 V XLR 3 pol l 15 m L2 0007860 Battery DC cable XLR 4 pin l 0 5 m L2 0008499 Battery DC cable XLR 4 pin l 3 m L2 0008500 Battery adapter plate for Anton Bauer L2 0008071 V Mount Battery adapter plate L2 0008070 Center mount yoke L2 0008078 Fixed center mount yoke L2 0008080 Rail mount adapter for SkyPanel PSU L2 0008082 Super clamp adapter for Sk...

Страница 76: ......

Отзывы: