51
T
rouble-Shooting
9. Trouble-Shooting
Display
Display
Cause
Remedy
RDY LED does not illuminate
CAP-MANUAL illuminates red
Integrated Capping Shutter fault
• Shut camera door
Camera not ready
• Press CAP-Manual key
(e.g. movement mechanism open)
• Manually check Integrated Capping Shutter
movement and accessibility of end stops
CAP-MANUAL blinks red
Error with external Capping Shutter
• Check external capping shutter
and extension cable
All LEDs blink
Singleframe EPROM in the camera
• Have camera modified by an
missing (camera not modified
ARRI service center
for singleframe)
RDY LED blinks red
1) Exposure time set outside
1) Set camera without electronically
acceptable range or 0 seconds
adjustable mirror shutter to 1/8s to 999s
Set camera with electronically adjustable
mirror shutter to 1/128s to 999s