background image

KW8

Ver. 1.2

15

9. INSTALLATIoN

KW8 may be either floor or ceiling mounted. 

For floor-mounted installations, the KW8 is supplied with four rubber mounting feet on the base. Install 
the unit only on flat surfaces.  Do not install the unit on uneven ground or platforms. 

For ceiling-mounted installations, four quarter-turn Fast Lock connections,located on the base of the 
unit, allow the KW8 to hang by the Fast Lock “C” clamps provided with the product. As shown in the 
picture below, two different orientations are available.

The supporting structure from which the unit is hung must be capable of bearing the weight of the unit 
and must be sufficiently rigid so that it doesn’t move or shake while the KW8 is moving. 

For ceiling-mounted installations, we recommend the use of a safety 
cable or chain to connect the KW8 and the suspension truss to avoid 
an accident should the main fixing point fail and the fixture fall. Ensure 
the iron cable or chain can bear the weight of the entire unit. You may 
attach the safety cable/chain to the attachment point located on the 

base of the fixture, as shown in the picture above.

Safety cable

Содержание KW8

Страница 1: ...KW8 Ver 1 2 KW8 USER GUIDE English...

Страница 2: ...Product Overview 8 6 1 MOVEMENT 8 7 CONNECTING THE UNIT 9 7 1 BACK PANEL CONNECTORS 9 7 2 MAINS POWER CONNECTION voltage selector 9 7 3 AUDIO CONNECTION 11 7 4 DMX CONNECTION 11 7 5 VIDEO CONNECTION...

Страница 3: ...the respective country specific regulations Waste Electrical and Electronic Equipment WEEE Please dispose of this product at the end of its operational lifetime by bringing it to your local collectio...

Страница 4: ...the flexibility of the Owl will offer an almost limitless number of solutions and in some cases reduce the amount of speakers required for an installation The Owl is part of K array s portfolio of co...

Страница 5: ...s such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two bl...

Страница 6: ...evel of 90 dB or over for an extended period of time If you experience ringing in your ears or muffled speech stop listening and have your hearing checked The louder the volume the less time is requir...

Страница 7: ...external heat source such as a hair dryer Carrying handling and installing the device The device contains sensitive components Do not drop disassemble open crush bend deform puncture shred incinerate...

Страница 8: ...KW8 Ver 1 2 8 Weight 10 kg 22 1 lbs 6 Product Overview 6 1 MOVEMENT 180 540 WARNING Do not obstruct the path of the speaker s movement...

Страница 9: ...cted audio equipment mixing consoles processors etc must be connected to the AC power distribution in a proper way preserving AC line polarity and ground connection such that all grounding points are...

Страница 10: ...ted to 230 VAC mains power To use the device on 115 VAC of mains power you will need to move the voltage selector to the correct value before connecting The voltage selector is located at the bottom o...

Страница 11: ...next unit by connecting the AUDIO OUT plug on the first unit to the AUDIO IN plug of the second one 7 4 DMX CONNECTION The unit operates using the digital DMX 512 1990 signal Connection between the co...

Страница 12: ...or must be plugged into the last unit DMX OUT panel connector of the DMX line 7 5 VIDEO CONNECTION The K OWL features a HD SDI camera supporting multiple output formats As default the camera outputs a...

Страница 13: ...A023 K OWL 4 A034 K OWL A just add 11 to the previous address To select the addresses proceed as follow 1 Press the UP DOWN key until you reach the required DMX channel The numbers on the display will...

Страница 14: ...ble time reaction to DMX signal fast to slow 248 255 Slow reaction time to DMX signal 6 Volume 0 255 Volume 0 dB to 7 Coverage 0 Wide coverage 255 Narrow coverage 8 Delay 0 Delay 0 ms 13 Delay 1 ms 24...

Страница 15: ...picture below two different orientations are available The supporting structure from which the unit is hung must be capable of bearing the weight of the unit and must be sufficiently rigid so that it...

Страница 16: ...the unit in for service In this instance you will be provided with an RA Return Authorization number which should be included on all shipping documents and correspondence regarding the repair Shipping...

Страница 17: ...kHz 3 dB for 1W 8 Damping factor 100 Hz 500 THD N 1kHz 1 W 0 010 AC POWER Connector 1 x PowerCon Nominal voltage 115 230 Vac Operating Range 85 130 Vac 60Hz 190 240 Vac 50Hz I Nom 2 A at 115 Vac 1 A a...