Arada Farringdon Stoves 

 

 

FIRE DOOR ROPE  
REPLACEMENT 

 

Periodically, visually check over the fire door rope 
seal for any damage, cuts or tears and any  
detached sections. It is important to maintain these 
seals in good condition at all times 

 

The rope gasket can be replaced, using the      
universal rope kit (Available from Arada),      
please follow the instructions below : 
 

 

Ensure the appliance is cold. 

 

 

Lift the door off the appliance and lay onto a 
flat surface with the rear face upwards.  

 

 

Carefully remove the old rope gasket and 
old adhesive. Take note of the layout of the 
old rope seal. Ensure no traces of the old  

   

adhesive or rust / flaky paint is present, as  

   

this will result in a unsound joint. 

 

 

Apply the rope adhesive following the  

   

instructions on the bottle. 

 

 

Press the rope gasket into the channel on 
the rear of the door casting, following the 
same layout as the old rope seal. See Fig. 8. 

 

 

Just before the final end, cut the rope seal to 
length and glue into position. 

 

 

 

 

 

 

 

 

 

Allow 30 minutes, before refitting the door to 
the appliance. 

 

 

 

FIRE DOOR GLASS 
REPLACEMENT 
 

In the event of the door glass being broken it can 
easily be replaced. Please follow : 
 

 

The door should be lifted off the hinges so 
that the operation can be carried out on a 
work bench or similar level surface. 

 

 

Unscrew the four screw fixings, securing the 
glass clips and remove, both clips and  

   

fixings. 

 

 

Carefully remove any pieces of broken 
glass, and sealing gasket, wearing suitable 
gloves as protection. Take note of the  

   

position and joint of the rope gasket. 

 

 

Replace the glass rope gasket; start at the 
bottom of the window, centrally, push the 
adhesive side of the rope into the groove on 
the rear of the casting. Gradually work your 
way around until the end of the rope meets. 
See Fig. 9. 

 

 

Re-seat the new glass, ensuring the glass 
sits flat against the gasket. See Fig. 10. 

 

 

Replace the four retaining clips and fixing 
screws. Do not over tighten the fixings as 
damage may occur to the glass. See Fig.11. 

 

 

Refit the door assembly back onto the stove; 
carefully lift the door over the hinge and slot 
into place. 

Fig. 8. Rope Replacement 

Fig. 9. Lining Up Gasket Rope 

Joint 

Rope 
Gasket 

Note: Images fig 8 & 9 for reference only 

Содержание Farringdon 16

Страница 1: ...Operating Installation Manual Rev 01 Mar Farringdon 16 Wood Stove BK660 UL1482 11 or ULC S629 00 ver 01...

Страница 2: ...installing your wood burning stove If you are in any doubt about the instruction to install your appliance correctly we suggest to call a professional master installer A wrong installation may result...

Страница 3: ...ance to Combustibles 16 18 Firebox Liner Panels 19 Final Check List 20 Summer Storage Non Usage 20 Page No SERVICE MAINTENANCE Annual Maintenance 21 Cleaning 21 Chimney Sweeping 21 Door Glass 21 Outer...

Страница 4: ...es must be safe and legal If your Farringdon stove is not installed correctly it may cause a house fire To reduce the risk of fire the installation instructions must be followed carefully Do not allow...

Страница 5: ...Use gloves to provide additional grip THE PRINCIPLE OF THE STOVE Your Arada stove is built to the highest standard of craftsmanship using the best materials and the most modern equipment available It...

Страница 6: ...liance body you should find the following Part Description Visual Aid not to scale Farringdon 16 1 Fuel Retainer 1 2 Throat Plate 1 3 Ash Pan 1 4 Throat Plate Insulation Blanket 1 5 Instruction Manual...

Страница 7: ...ld find the following Arada Farringdon Stoves 7 Description Visual Aid not to scale Farringdon 16 6 Back Side Liners 4 7 Front Side Liners 2 8 Rear Liner 2 9 Grate Bars 12 10 Stove Mitten Hot Glove 2...

Страница 8: ...203mm sur les cotes et a l arriere Refer to the Installation manual for additional clearance information Installation instructions and Operating instructions Se referrer a la notice d utilisation pour...

Страница 9: ...g s 5 7 Height mm inch 659 26 Width mm inch 533 21 Depth mm inch handle removed 330 13 Depth From Back To Centre Of Flue mm inch 125 5 Flue Diameter mm inch 152 6 Weight Packed Kg lbs 84 185 Weight N...

Страница 10: ...hould be taken to achieve it Ideally the appliance should stand on a constructional hearth of non combustible materials not less than 125mm 5 thick conforming to Building Regulations Dimensions of the...

Страница 11: ...will invalidate the warranty Please remember that chimney draught is dependent on four main factors Flue gas temperature Flue height Flue size Flue terminal The stove must be connected to a suitable a...

Страница 12: ...slowly in a closed appliance it produces moisture tar and Creosote which will create condensation and deposits in the chimney This effect can be minimised by burning hard for a short period about 20...

Страница 13: ...eneral Factory built chimneys and chimney units must be installed in accordance with the tempera ture and pressure conditions detailed in the manufacturers instructions Temperature and pressure limits...

Страница 14: ...1 5mm Thick Minimum Non Combustible Register Plate Minimum 1 5mm Thick Steel A code approved masonry chimney with a flue liner with a 6 inches diameter 15 24cm Typical Metal Insulated Chimney System...

Страница 15: ...p plate Insulated High Temperature 6 diameter Flue liner rigid or flexible Minimum 16 high Connector rigid or flexible between flue collar of stove and flue liner Sample installation into existing chi...

Страница 16: ...nd hot ashes when the stove door is opened for refuelling etc Radiated heat caused by stove over firing Spillage of creosote as a result of a chimney fire The surface used must be non combustible and...

Страница 17: ...on Stoves 17 Stove clearances on floor protection plate The floor protection plate must be of Non Combustible Material Minimum dimensions listed may be increased A B C USA D Canada 203mm 203mm 406mm 4...

Страница 18: ...478mm 305mm 406mm 458mm 19ins 12ins 16ins 18ins A B 458mm 267mm 18ins 10 5ins Corner Installation clearances For Alcove Installation The ceiling can be 72ins 1828mm above the base of the stove or 16in...

Страница 19: ...iner s into the back of the firebox Lift the throat plate into position with the front above the perforated air tube Align the 2 tabs on the throat plate with the location slots in the rear air bar an...

Страница 20: ...e installer at the time of installation Please answer all questions as fully as possible Arada stoves cannot be held responsible for the chimney or installation SUMMER STORAGE NON USAGE Please ensure...

Страница 21: ...ificate Of Chimney Sweeping The whole flue way including the outlet must be swept at least twice per burning season It is important that the flue ways flue pipe and chimney be cleaned prior to lightin...

Страница 22: ...minutes before refitting the door to the appliance FIRE DOOR GLASS REPLACEMENT In the event of the door glass being broken it can easily be replaced Please follow The door should be lifted off the hi...

Страница 23: ...11 Tightening The Glass Clip The images used on pages 22 and 23 illustrating the door rope and glass replacement are generic images and may differ from the stove you have but the procedure is identica...

Страница 24: ...covered in this manual please contact your Arada dealer Please keep all repair receipts safely Please ensure you have this manual available when an engineer visits so they can complete the service re...

Страница 25: ...termittent use WARNING NEVER BURN PLASTICS OR HOUSEHOLD WASTE IN YOUR STOVE WARNING NEVER BURN LIQUID FUELS IN YOUR STOVE Never use any type of liquid fuel to start or refresh your stove and keep all...

Страница 26: ...burn time to refuelling dependant on fuel quality and moisture content Please Note The high temperature paint acquires durability by being cured during the initial firings of the appliance It will gi...

Страница 27: ...e structural damage to the chimney Do not use the appliance until the chimney and connector have been inspected and any damaged parts have been repaired or replaced This should be done by a registered...

Страница 28: ...IGHT is High air The air wash system so called because its pre heated high speed air washes across the inner face of the door glass keeping it clear This also provides an over draught to the fuel bed...

Страница 29: ...ntrol for the catalyst bypass is on the left and right side of the stove in the position shown in Fig A Actuation is as shown on the label on the Left hand side The bypass should be placed in the open...

Страница 30: ...ire door whilst the appliance is in use WITHOUT the use of the stove mitten or suitable gloves serious injuries may occur Caution must be given when re fuelling the appliance always keep the stove mit...

Страница 31: ...r Top Rear AFS3745 7 Complete Fire Door AFS3670 20d Side Liner Bottom Rear AFS3750 8 Handle Assembly AFS3680 21 Direct Air Adaptor AFS3755 9 Gasket and Glass Clips AFS1361 22 Grate Bar Support AFS3760...

Страница 32: ...pliance being serviced and checked annually by a qualified heating engineer with documentation to be retained and produced in the event of a claim being made Claims are not valid where installation do...

Страница 33: ...entation must be retained and produced in the event of a warranty claim This guarantee specifically does not cover accidental damage misuse wear tear The use of non Arada replacement parts will invali...

Страница 34: ...User Notes 34...

Страница 35: ...Liners 8 Throat Plate Throat Plate Insulation Blanket Door Riddle Handle Ash Pan Operating Installation Manual Stove Mittens Assembled By Checked by Date of Purchase Name and Address of Supplier Arada...

Отзывы: