IMPORTANT SAFETY INSTRUCTIONS

Please read all instruc�ons before use to prevent the risk of injury, fire, electric shock or damage. 

Use your air purifier safely by following the instruc�ons in this User Manual.

 

DO NOT

 use the air purifier before removing the plas�c packaging from the filter. It is a fire 

hazard to use your air purifier with the filter s�ll inside its packaging.

 

DO NOT

 use the air purifier if it has been dropped, damaged, le� outside, dropped in water, 

       is defec�ve or not working properly. 

 

DO NOT

 use the air purifier if the cord or plug looks damaged. 

 

DO NOT

 use the air purifier near gas appliances, fire places, stoves, candles, or hea�ng devices.

 

DO NOT

 use the air purifier in an area with insect repellents, burning incense, toxic fumes, 

flammable dust or oxygen tanks. Always leave at least 1.5 m of clear space from any oxygen 
being administered.

 

DO NOT

 touch any part of the air purifier or its plug with wet hands. 

 

DO NOT

  run  the  power  cord  under  furniture,  other  appliances,  carpet,  or  cover  with  rugs, 

runners or floor coverings.

• 

ALWAYS

 tuck away the power cord to prevent tripping accidents.

 

DO NOT

 use the air purifier and power plug on wet or damp surfaces.

 

DO NOT

 put the air purifier in water or liquids. 

 

DO NOT

 use the air purifier outdoor. 

 

DO NOT

 keep air purifier under an air condi�oner to help prevent moisture ge�ng into the unit.

• 

DO NOT

 use the air purifier in a room that can have a big change in temperature. This will help 

minimise the risk of condensa�on.

• 

DO NOT

 put fingers or any objects into the air inlet/outlet of the air purifier.

• 

DO NOT

 use a defec�ve air purifier or a�empt to repair/adjust any electrical or mechanical 

func�ons, this may cause danger and void the warranty.

 

DO NOT

 let children or people with reduced physical or mental capabili�es to use or clean the 

air purifier. 

 

DO NOT

 let children play with this appliance or its packaging including plas�c bag. Children 

must be supervised around the air purifier to help keep them safe. 

 

DO NOT

 sit on the air purifier or put any objects on top of the unit.

 

DO NOT

 block/obscure the air inlet or outlet. Keep free of anything that could reduce airflow.

• 

DO NOT

 fit the air purifier with a different power supply unit. 

 

DO NOT

 spray air fresheners, perfumes or oils on or near the filter. 

• 

DO NOT

 clean the air purifier or change the filter with the power cord plugged in.

• 

DO NOT

 use the air purifier for commercial purposes. This appliance is for household use only.

• 

It is recommended to NOT use the unit with an extension cord to avoid electrical shock or spark.

• 

TURN OFF

 the air purifier when it is not being used. Hold the plug and remove it from the 

electrical source. Do not unplug by pulling the cable.

• 

WARNING: 

This air purifier does not remove carbon monoxide or radon from the air. It must 

not  be  used  to  prevent  or  clean  up  accidents  with  combus�on  processes  and  hazardous 

chemicals.

   KEEP THESE INSTRUCTIONS IN A SAFE PLACE.

4

Содержание AV-P120

Страница 1: ...AV P120 AV P120B White and Black This user manual provides safety and opera ng instruc ons Please read this user manual thoroughly before using the product This user manual will help get your air pur...

Страница 2: ...Copyright 2019 2021 Arovec Australia All rights reserved...

Страница 3: ...Filter Package 1 User Manual 1 Warranty Card 4 5 6 7 8 9 11 14 14 14 15 16 18 18 Power Supply Rated Power Standby Power Opera ng Condi ons Noise Level Coverage Area Night Light Net Weight Product Dime...

Страница 4: ...T use the air puri er in a room that can have a big change in temperature This will help minimise the risk of condensa on DO NOT put ngers or any objects into the air inlet outlet of the air puri er D...

Страница 5: ...lthy with AV P120 Product Features This air puri er uses mul ple stage ltra on system which removes 99 97 odour smoke and airborne contaminants as small as 0 3 m 1 Preliminary Filter Captures large pa...

Страница 6: ...Light Display OFF Bu on 6 Timer Indicators 7 Timer Bu on 8 Air Outlet 9 Air Inlet 10 Base Cover 11 Power Cord 12 Filter Pack 12 a Preliminary Filter 12 b H13 True HEPA Filter 12 c Ac vated Carbon Filt...

Страница 7: ...clockwise to unlock the cover b Remove the base cover and lter from the air puri er c Remove the lter from it s plas c packaging 2 Replace the lter Figure 1 2 a Put the lter back into the air puri er...

Страница 8: ...efficiency place the air purifier on a flat and level surface with the control panel facing up Leave at least 40 cm of clear space around each side of the air purifier when it is on Figure 2 1 Shut ne...

Страница 9: ...the next fan speed level Memory Func on The air purifier keeps the control setting when it s turned OFF when the air purifier is plugged in it will remember its previous fan speed setting The fan spe...

Страница 10: ...is set the air purifier will continuously operate until it is manually turned OFF To cancel the timer tap until all timer indicators turn OFF Light Bu on Tap to adjust the LED light colour or turn OF...

Страница 11: ...epending on how much you use your air purifier and how much pollution is in the air You don t need to wait for to light up for changing the filter You may need to change the filter if you notice any o...

Страница 12: ...air puri er with a vacuum cleaner DO NOT use water or any liquids to clean the puri er b Remove the new lter from its packaging 3 Place the new lter into the air puri er and put the base cover back o...

Страница 13: ...urn OFF which indicates that the air puri er has been reset You can use the air puri er with the new lter 2 If the lter was replaced before the lights up Plug in the air puri er a er replacement but d...

Страница 14: ...eaner to remove large particles hair and dust from the preliminary filter DO NOT clean the filter with water or any other liquids Figure 4 1 If not using the AV P120 for an extended period of time it...

Страница 15: ...increase the fan speed The air puri er is e ec ve in an area up to 12 m2 Ensure that the doors and windows are closed Check if the lter needs to be replaced Remove any debris blocking the air ow inle...

Страница 16: ...ty and the failure does not amount to a major failure Product name Model Standard warranty period Addi onal warranty Record your order details here This will help if you have any warranty ques ons in...

Страница 17: ...or an authorised agent Damage caused by using filters other than original Arovec replacement filters All other conditions that are not covered by Arovec warranty as listed in the What is Covered secti...

Страница 18: ...ree to contact our helpful customer support team with any questions or inquiries regarding your product Your satisfaction is our priority Customer support Ausbrilliant Brands PO Box2 Ermington NSW 170...

Страница 19: ......

Страница 20: ...V0221 1...

Отзывы: