DIMENSIONAL DATA
TROUBLESHOOTING
Product discharged from exhaust outlet.
y
Check for diaphragm rupture.
y
Check tightness of (14) diaphragm screw.
Air bubbles in product discharge.
y
Check connections of suction plumbing.
y
Check “O” rings between intake manifold and inlet side
fluid caps.
y
Check tightness of (14) diaphragm screw.
Motor blows air or stalls.
y
Check (176) check valve for damage or wear.
y
Check for restrictions in valve / exhaust.
Low output volume, erratic flow, or no flow.
y
Check air supply.
y
Check for plugged outlet hose.
y
Check for kinked (restrictive) outlet material hose.
y
Check for kinked (restrictive) or collapsed inlet material
hose.
y
Check for pump cavitation -- suction pipe should be sized
at least as large as the inlet thread diameter of the pump
for proper flow if high viscosity fluids are being pumped.
Suction hose must be a non-collapsing type, capable of
pulling a high vacuum.
y
Check all joints on the inlet manifolds and suction con-
nections. These must be air tight.
y
Inspect the pump for solid objects logged in the dia-
phragmchamber or the seat area.
INLET
OUTLET
Exhaust Port
1-1/2 - 11-1/2 NPTF
19-11/32” (491.3 mm)
9/16” Slot (14.3 mm)
10-1/16”
(255.6 mm)
24-3/4”
(628.7 mm)
2-1/2”
(63.5 mm)
Air Inlet
3/4 - 14 NPTF
26-9/32”
(667.4 mm)
2-1/2” Sanitary Flange
2-1/2” Sanitary Flange
13-9/16”
(344.5 mm)
(Dimensions shown are for reference only, they are displayed in inches and millimeters (mm)).
21-5/8” (548.2 mm)
16-3/16” (411.1 mm)
12” (304.8 mm)
3”(76.2mm)
9-1/16”
(230.2 mm)
10-1/16”
(255.6 mm)
Dotted lines show optional
67213 muffler kit.
2-1/2” Sanitary Flange
Dotted lines show optional
67263 muffler assembly.
Figure 4
Содержание PM20 Series
Страница 10: ...Page 10 of 12 PM20X X X BXX en ...
Страница 11: ...PM20X X X BXX en Page 11 of 12 ...
Страница 12: ...Page 12 of 12 PM20X X X BXX en PN 97999 1114 ...