507746-01
Issue 1821
Page 25 of 39
Target CFM Tables
BCE7S24M Blower Performance
0 through 0.80 in. w.g. External Static Pressure Range
"Adjust"
Jumper
Setting
Jumper Speed Positions
"HEAT" Speed
"COOL" Speed
1
2
3
4
1
2
3
4
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
+
465
690
900
1050
465
690
900
1050
NORM
425
620
825
950
425
620
825
950
-
385
560
735
850
385
560
735
850
NOTES
:
•
The effect of static pressure, filter and electric heater resistance is included in the air volumes listed.
•
First stage cooling air volume is 70% of COOL speed settings. Continuous fan speed is approximately 28%, 38%, 70% and
100% (Jumper selectable) of the same second-stage COOL speed selected, minimum 250 cfm.
•
Zone Control applications - minimum blower speed of 250 cfm.
BCE7S30M Blower Performance
0 through 0.80 in. w.g. External Static Pressure Range
"Adjust"
Jumper
Setting
Jumper Speed Positions
"HEAT" Speed
"COOL" Speed
1
2
3
4
1
2
3
4
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
+
660
880
1100
1320
660
880
1100
1320
NORM
600
800
1000
1200
600
800
1000
1200
-
540
720
900
1080
540
720
900
1080
NOTES
:
•
The effect of static pressure, filter and electric heater resistance is included in the air volumes listed.
•
First stage cooling air volume is 70% of COOL speed settings. Continuous fan speed is approximately 28%, 38%, 70% and
100% (Jumper selectable) of the same second-stage COOL speed selected, minimum 250 cfm.
•
Zone Control applications - minimum blower speed of 250 cfm.
BCE7S36M Blower Performance
0 through 0.80 in. w.g. External Static Pressure Range
"Adjust"
Jumper
Setting
Jumper Speed Positions
"HEAT" Speed
"COOL" Speed
1
2
3
4
1
2
3
4
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
+
900
1225
1380
1545
900
1225
1380
1545
NORM
810
1125
1275
1400
810
1125
1275
1400
-
730
1000
1135
1265
730
1000
1135
1265
NOTES
:
•
The effect of static pressure, filter and electric heater resistance is included in the air volumes listed.
•
First stage cooling air volume is 70% of COOL speed settings. Continuous fan speed is approximately 28%, 38%, 70% and
100% (Jumper selectable) of the same second-stage COOL speed selected, minimum 250 cfm.
•
Zone Control applications - minimum blower speed of 250 cfm.