![Armitage Shanks Sensorflow 21 A4168AA Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/armitage-shanks/sensorflow-21-a4168aa/sensorflow-21-a4168aa_installation-instructions-manual_2973808021.webp)
10 CLEANING CHROME SURFACES
When cleaning chromed products use only a mild detergent, rinse & wipe dry with
a soft cloth. Ideally clean after each use to maintain appearance.
Never use abrasive, scouring powders or scrapers. Never use cleaning agents
containing alcohol, ammonia, hydrochloric acid, sulphuric acid, nitric acid,
phosphoric acid or organic solvents. Use of incorrect cleaning products / methods may result in chrome
damage which is not covered by the manufacturer’s guarantee.
21
9.3
Isolating valve
strainer cap
strainer screen
isolating valve
direction
of flow
Isolation valve (supplied with this product) MUST be fitted to permit future maintenance of the product.
A strainer (filter) is built into this valve.
Isolation valve should be installed in an easily accessible location.
When the isolator screw slot is parallel to the valve body, the valve is open & permits water to flow. To
close the valve, rotate the isolator screw 90°.
The filter can be checked & cleaned by unscrewing the cap using a 22mm A/F spanner. Expect some
water to escape. The isolating valve can be closed to permit servicing of the solenoid valve, or to remove
the product completely.