![Armitage Shanks Avon 21 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/armitage-shanks/avon-21/avon-21_installation-instructions-manual_2973795009.webp)
9
8
OUTLET DETAILS
1
4
2,5
1
2
1.
2.
3,8 L/min
Q
300KPa
This product is factory fitted with a laminar PCA regulated outlet
which is secured with an anti-vandal (AV) housing.
Table 3 shows the flow rate performance for the flow regulator outlet
Table 3 Flow rate data (Q=flow rate)
To replace/clean/service the outlet, use the outlet
key supplied with the product to unscrew the AV
housing.
1.
Using the side of the key marked
“junior” locate the key into the inner ring of the
housing.
2.
Unscrew housing. Change the outlet
& re-secure the housing with the key, ensuring
the seal is in place.
Ensure the outlet housing is adequately tightened
to prevent leaks & run back.
9
RUN TIME ADJUSTMENT
This is a water saving product & is supplied set with a short run time. A
run time of typically 5 to 15 seconds will suit most applications.
The run time can be adjusted as detailed below; first the handle must be
removed.
1 & 2 Handle removal
To remove the handle prise out the
small grommet located at the rear of the
handle. Insert the 2.5mm hexagon key
(supplied) into the hole & undo the
grub screw a few turns.
The handle should lift off from
the tap body.