XCHANGE ERV

EXTERNAL MOUNT

XEM - INSTALLATION & OPERATION MANUAL

WARNING

Improper installation, service, maintenance or use can cause 
explosion, fire, electrical shock or other conditions, which 
may cause personal injury or property damage and will 
void the warranty.  Check with Armcor Air Solutions for any 
information required on this equipment.

DANGER

Electrical shock can cause personal injury or death.  Before 
performing any work on this equipment, the electrical 
supply must be turned off to avoid the possibility of shock, 
injury or damage to the equipment.  There may be more 
than one power supply circuit.  

 

The XEM series is the standard heat recovery ERV solution for rooftop, ground level or plant 
room applications.  Available with forward curved centrifugal fans or with EC Plug Fans, these 
ERV units utilize the Xchange plate heat exchanger to recover the energy from the exhaust air 
and transfer it to the incoming fresh air, resulting in significant energy savings. Both enthalpy 
and sensible heat exchange media are available. 

Every proposed installation must be subject to an engineered design by a mechanical services 
consultant. Armcor Air Solutions is not responsible for performance of equipment in applications 
for which the equipment was not designed or specified.

•  Only trained and qualified personnel should install, repair 

or service heat recovery and/or air handling equipment.

•  Installing and servicing equipment can be hazardous due 

to electrical and mechanical components.

•  When working on equipment, observe precautions in all 

literature, tags and labels attached to or shipped with the 

unit.  Follow all safety codes and guidelines.  Wear work 

gloves, safety goggles and protective clothing.

•  All work must comply with relevant SAA wiring rules 

and local authority codes.  Installers must ensure that all 

statutory regulations and by laws have been addressed.

•  Installers must ensure that the structures built to support 

the equipment have been suitably constructed for the 

purpose, all safety precautions have been applied prior 

to installation, and all preparation work has been suitably 
sized and installed for its purpose.

EQUIPMENT APPLICATION

SAFETY CONSIDERATIONS

INSTALLATION BY AUTHORISED PERSONNEL  

 1

Содержание XEM 500

Страница 1: ...XEMINSTALLATION OPERATIONMANUAL XCHANGEERV EXTERNALMOUNT XEM500 XEM900 XEM1200 XEM1700 XEM2000 XEM2500 XEM3500 XEM4500 XEM5000 XEM6000 XEM7000 XEM8000 ...

Страница 2: ......

Страница 3: ...ge media are available Every proposed installation must be subject to an engineered design by a mechanical services consultant Armcor Air Solutions is not responsible for performance of equipment in applications for which the equipment was not designed or specified Only trained and qualified personnel should install repair or service heat recovery and or air handling equipment Installing and servi...

Страница 4: ...e pad to be used under the base frame and flexible couplings be fitted to the supply and return ducts to reduce any vibration transfer The location of the fresh air inlets must adhere to the Australian Standards 1668 2 The fresh air intake should be positioned clear of any objects which could obstruct the airflow and be a minimum distance of 6 metres from any exhaust discharge ducts from this unit...

Страница 5: ...NOTE All units should be lifted into position using SLINGS and not CHAINS Chains may damage exterior finish on the fan unit Where units have to be craned into position installers must check unit weight is within the safe tolerance of the working capacity of the crane Prepare for lifting with spreaders as you would do with lifting air conditioning equipment When lifting equipment never stand under ...

Страница 6: ...construction and commissioning Where a Heat Exchanger is incorporated in the equipment warranty is void if filters are not fitted IMPORTANT NEVER OPERATE A UNIT WITHOUT FILTERS FITTED TO THE RETURN AND FRESH AIR INTAKES The power requirement and voltage are detailed on the equipment technical specifications available on our website www armcor com au and are on the identification serial no plate at...

Страница 7: ...ailable for units fitted with Certrifugal Fans OPTION 1 AND 2 DO NOT REQUIRE ANY CHANGES TO THE FAN POSITIONS INSIDE THE UNIT RETURN AIR Air that is drawn from conditioned area EXHAUST AIR Ducted to outside the building or into the roof space if adequate ventilation is available FRESH AIR Use a fresh air cowl or grill to introduce fresh air SUPPLY AIR Connect to the Airconditioning system or direc...

Страница 8: ...eaned once a month and the filter media should be replaced every 12 months Repeat the monthly schedule Check blower wheels for dirt build up and tightness on shaft Check all cabinet panels for correct fitting alignment and seals and clean cabinets as required Ensure no insulation has been detached from the panels All electrical terminals should be checked for tightness IMPORTANT Ensure the with ma...

Страница 9: ... and travel changes for work performed or parts supplied outside of all capital cities in Australia Field wiring refrigerant pipe run between units the condensation drainpipe or other accessories Any warranty work performed by Armcor Air Solutions outside of Melbourne metro area will require the installing contractor to provide free of charge Oxy Acetylene Equipment Dry Nitrogen Vacuum Pump Refrig...

Страница 10: ...ons Ensure supply cable is correct size Check the required supply voltage is available on all phases Check overload settings are correct if applicable FILTERS Check that both the fresh air and return air have adequate filters before starting unit STARTING UNIT Check Fans and Air Flows Turn on all circuit breakers Make sure all dampers are open Turn on control circuit and activate fans Turn on supp...

Страница 11: ...rn Air Flow Total of all inlets L s Total System external resistance Pa Measured downstream of fan outlets plus upstream of Coil s Estimate of Fresh Air Make Up or L s ELECTRICAL Supply Voltage Supply Unit Fan Motor Amps Exhaust Fan Motor Amps Total Unit Amps Thermostat Settings ºC Thermostat Operating Correctly Y N Contactors Relays Operating Correctly Y N All Terminals Checked for Tightness and ...

Отзывы: