OPERATING 

6. 

Plug in the power cord to a power  

  outlet and the current ambient air  
  temperature will be displayed on   
  the digital thermometer. If this  

 

  temperature is above 35C, freezing  
  pipes may not be possible. Should  
  the Icecap-Pro pipe freezer have   
  been stored in a hot location such  
  as a car on a hot summers day,
  before using press the power button
  and the cooling fans will start, the  
  temperature will lower to the  

 

  ambient room temperature.

7.

  Press the freeze button 

 and the 

  jaw temperature will begin to drop.

7

6

8

.  

Factors that affect the freezing 

  times are:

 

a

   The ambient air temperature.

 

b

 

  The size of the pipe. Larger pipes  

   

take longer to freeze than smaller  

   

pipes.  

 

  The quality of thermal contact 

   

between the freezing components  

   

and the pipe.

 d

   The temperature of water within  

   

the pipe.

 

e

   The level of solar radiation. If    

   

possible, keep out of direct sunlight.

 

f

  Contaminated water. Corrosion 

   

inhibitors or anti-freeze within 

   

central heating systems may slow  

   

or possibly prevent freezing in  

   

high concentrations.

IMPORTANT

The Icecap-Pro contains an 

accurate and fast responding 

digital thermometer. During 

the freezing process it may be 

noticed that the temperature 

rises a few degrees quite 

quickly before stabilising.  

This is not a fault with the 

machine but is caused by ice 

breaking away from an ice 

plug as it is being formed and 

being replaced by warmer 

water from below. 

Содержание Icecap-Pro

Страница 1: ...ICECAP PRO ELECTRONIC PIPE FREEZER INSTRUCTION MANUAL UNITED KINGDOM ...

Страница 2: ...ck fire and or serious injury SAVE ALL WARNINGS AND INSTRUCTIONS FOR FUTURE REFERENCE The term power tool in all of the warnings listed below refers to your mains operated corded power tool a Keep work area clean and well lit Cluttered or dark areas invite accidents b Do not operate power tools in explosive atmospheres such as in the presence of flammable liquids gases or dust Power tools create s...

Страница 3: ...se the risk of electric shock e When operating tools outdoors use an extension cord suitable for outdoor use Use of a cord suitable for outdoor use reduces the risk of electric shock f If operating a power tool in a damp location is unavoidable use a residual current device RCD protected power supply Use of an RCD reduces the risk of electric shock 2ELECTRICAL SAFETY 3PERSONAL SAFETY a Stay alert ...

Страница 4: ...dition that may affect the power tool s operation If damaged have the power tool repaired before use Many accidents are caused by poorly maintained power tools CONTINUED SAFETY INSTRUCTIONS 4 SERVICE a Have your power tool serviced by a qualified repair person using only identical replacement parts This will ensure that the safety of the power tool is maintained GENERAL INFORMATION a In the event ...

Страница 5: ...service The top jaw contains a thermocouple which is connected to the onboard digital thermometer If freezing a single pipe the top jaw should be utilised 1x 1 5m power lead Replacement part No 5 020 2x Thermo conductive paste Replacement part No 5 018 4x 22mm reducing inserts Replacement part No 5 021 4x 15mm reducing inserts Replacement part No 5 022 4x 10mm reducing inserts Replacement part No ...

Страница 6: ...Maximum span between jaws 2750mm Storage temperature 10C 35C Ingress protection IP22 The Icecap Pro should be tempered before use when stored in hot conditions i e adopt room temperature by switching on the power button and allowing the cooling fans to bring to room temperature IMPORTANT The water within the pipe should be completely static dripping taps should be temporarily plugged and be at roo...

Страница 7: ...rew to hold the jaw in place OPERATING 7 4 For UK pipe sizes less than 28mm reducing inserts will be required Select the correct inserts for the required pipe and apply contact paste to the main 28mm freeze head From the left hand side of the jaw slide the correct size reducing insert into the main freeze head and apply additional contact past onto the pipe This ensures good conductivity occurs be...

Страница 8: ...mperature b The size of the pipe Larger pipes take longer to freeze than smaller pipes c The quality of thermal contact between the freezing components and the pipe d The temperature of water within the pipe e The level of solar radiation If possible keep out of direct sunlight f Contaminated water Corrosion inhibitors or anti freeze within central heating systems may slow or possibly prevent free...

Страница 9: ...ge ice plug is formed Double check that the ice plug is fully formed by opening taps or slackening joints etc before cutting pipes As the application and end use of the ICECAP Pro is beyond our control we shall not be liable for any loss or damage direct or consequential arising out of the use of or the inability to use the product or its components in a safe and effective manner IMPORTANT CHECKS ...

Страница 10: ... 15C it is very likely to be an irregularity within the pipework rather than the machine This can be confirmed by carrying out a test freeze using a short piece of pipe filled with water where the freezing process of the ice plug can be observed COOLANT TOP UP In the event of the coolant pump making an unusually loud noise and the freezer heads becoming warm Unplug the unit unscrew the reservoir f...

Страница 11: ...r than authorised Armarge repair staff To claim this guarantee you will need to provide proof of purchase to the seller or register your new Icecap Pro on our website www armarge com and to be kept up to date on new products and special offers FOR EU COUNTRIES ONLY Do not dispose of electric tools with domestic waste In accordance with European directive 2002 96 EC on waste electrical and electron...

Страница 12: ...www armarge com ...

Отзывы: