41
Enable Alarm:
This will switch ON/OFF the alarm in camera
Alarm Duration: From the drop-down list, select the length of the alarm (10sec, 30sec, 1
min, 5min, 10min, Non-Stop). This option will determine how long the ALARM signal
should be ON after it gets detected.
Alarm Trigger: You can change the Alarm Trigger mode in the Network camera:
Motion Detect: Activates or deactivates the alarm when the Motion is found based
on motion detection setting
Ethernet Lost: Activates or deactivates the alarm when the network connection is
down or network cable is tampered with
Audio Alarm: Activates or deactivates the alarm at high audio level based on the
value set in Alarm Level in Audio Page.
For External Triggers Input : Select one of the following options
ON: Corresponds to the ALM-IN in the IPNC, you can use GPIO connector.
OFF: Corresponds to the ALM-IN in the IPNC, GPIO connector is shut down.
For External Triggers Output : Select one of the following options
ON: Corresponds to the ALM-OUT in the IPNC, you can use GPIO connector.
OFF: Corresponds to the ALM-OUT in the IPNC, GPIO connector is shut
down.
On Alarm :
You can change the Alarm Actions by setting appropriate check boxes
Upload via FTP: Activates or deactivates the alarm recording upload to FTP
File Format: User needs to select this option based on drop-down Menu. AVI
or JPEG format is supported
Save Into Local Storage: Activates or deactivates the alarm recording to be saved
to SD card.
File Format: User needs to select this option based on drop-down Menu. AVI
or JPEG format is supported
Storage Location: SD CARD/USB or other memory is supported in this version.
Upload via SMTP: Activates or deactivates the alarm recording upload to SMTP.
File Format: User needs to select this option based on drop-down Menu. AVI
or JPEG format is supported
Attached File numbers: Type the number of images per email. The default
value is 2. The limit is 20.
Play Audio: Selects the audio playback based of alarm detection
Alarm Audio Files: User needs to select the Alarm Wave Files that needs to be
played
Alarm I/O :
Input/Output: For both Digital Input and Digital Output, select the Active Type as
Low or High from the respective drop-down lists. Active Type means low trigger or
high trigger (or triggers to high or triggers to low when output). The alarm can be
triggered with the digital signal.
RS485: This is disabled for current release.
Note:
Before starting the function, you have to set the FTP, SMTP server parameters
should be entered through Network Page
Mail server should limit the file size of an e-mail (3 MB usually). For more