Clean and disinfect – bath systems and showering products
6
7
8
9
10
Activate the rinse setting.
If cleaning a bathtub: Open the
drain. Drain the bath of residual
disinfectant solution.
If cleaning a bathtub with air spa:
Place the spray handle into the
injection port. Press and hold the
trigger. Water must flow
from all air-jets/nozzles.
Rinse all parts clean. Make sure
all disinfectant is removed from
the bath system or showering
product.
If cleaning a bathtub with air spa:
Activate and run the air spa for 30
seconds until any remaining
water is removed from the
system.
After the last disinfection of the
day, dry the bathing or showering
product and the accessories.
Switch the MultiClean unit off.
Close the water supply.
1
Activate the disinfection
setting. Take the spray
handle and direct it towards
the product. Switch the unit
on.
If cleaning a bathtub: Close
the drain.
2
If cleaning a bathtub with air
spa: Place the disinfection
spray handle into the
injection port. Press and hold
the trigger. Disinfectant must
flow from all air-jets/nozzles
for at least 30 seconds.
4
Scrub all
disinfected
surfaces
throroughly.
5
Allow appropriate contact
time according to the
instructions of the
disinfectant. Wipe all other
areas and accessories with
a cloth soaked in
disinfectant solution.
3
Spray disinfectant on all
internal bathtub surfaces, on
all surfaces of showering
product, and on all surfaces
of all accessories.
Risk of injury
Do NOT use as
patient shower.