background image

001-04100-EN rev

. 2 

Safety Instructions

2

Intended Use

The 

BHM Turntable

 is a track accessory to be 

used with the 

BHM

  track  system  and  a  fixed 

ceiling lift in a homecare setting, at nursing 

homes and other assisted living centres. The 

BHM Turntable

 allows the ceiling lift to pass 

from a track path to another. Patient transferring 

is performed under the supervision of a trained 

caregiver as per the instructions outlined in this 

manual. All other uses must be avoided.
The 

BHM Turntable

 must only be used for the 

purposes stated above. It must be installed by 

ArjoHuntleigh

 authorized personnel as per local 

codes.

WARNING

: The 

BHM Turntable

 is not 

intended to be operated by the patient.  

In the event of a malfunction, the patient 

could get stuck.

WARNING

: The 

BHM Turntable

 is for 

transferring patients only. Do not use the 

BHM Turntable

 for any other purpose.

Using this 

BHM Turntable

 outside the scope 

of its intended use could lead to injuries.

Operational Life

This product is designed and tested for a useful 

life of seven (7) years or 10 000 cycles —

whichever  comes  first—at  maximum  safe 

working load (SWL). It is subject to preventive 

maintenance  as  specified  in  the  “Care  and 

Maintenance” section. 

A complete cycle is defined as the rotation of 

the 

BHM Turntable

 to the desired track path and 

its rotation to the initial track path.
Time equivalence between the number of 

cycles versus the number of years is made 

clear in the following table.

Cycles per Day

Years 

(10 000  cycles)

4

7

6

4.5

8

3.5

WARNING

: The manufacturer cannot 

ensure full safety for an accessory of which 

the life span has been exceeded. Wear may 

cause the breakage of a part and lead to a 

patient fall.

The life span is the safe operating time period 

before a complete overhaul is required.
Following are factors that have an impact on 

the lift’s life span:

•  aging of the unit;

•  transfers per day;

•  weight of the patient;

•  maintenance frequency.

Product Identification

The 

product’s 

identification 

number 

(specification,  model,  serial  number)  appears 

on  a  silver  label  fixed  inside  the  track  of  the 

BHM Turntable

.

How to Use this Manual

To ensure the safe operation of the 

BHM Turntable

, read the entire manual carefully 

before operating this product.
If anything is not completely understood, please 

contact your local 

ArjoHuntleigh,

 agent for more 

details. Failure to comply with warnings in this 

manual may result in injuries.
Keep this manual handy and refer to it as 

required. Make sure that all operators are 

regularly trained in the use of the product as per 

the information found therein.
The 

BHM Turntable

 must be used as per these 

safety instructions.
Anyone using the 

BHM Turntable

 must also 

have read and understood the instructions in 

this manual.
If there is anything you are not sure about, 

contact your local ArjoHuntleigh, representative.

Safe Working Load

The 

BHM Turntable

 has been designed to be 

used with ArjoHuntleigh ceiling lifts with a safe 

working load of 272 kg (600 lb) or less.

WARNING

: The 

BHM Turntable

 is intended 

to be used for residents whose weight is 

within a specified safe working load (SWL). 

Do not attempt to lift more than the lowest 

weight limit indicated on the following: 

•  the track system

• 

the “maximum load” label on the 

ceiling lift

•  on the spreader bar

•  on accessories

•  on the sling. 

Overloading any of these elements could 

lead to a patient fall.

Safety Instructions

Содержание 700.042 Series

Страница 1: ...BHM Turntable Serie 700 042XX Instruction for Use 001 04100 EN rev 2 March 2014...

Страница 2: ...oHuntleigh group of companies ArjoHuntleigh 2014 As our policy is one of continuous improvement we reserve the right to modify designs without prior notice The content of this publication may not be c...

Страница 3: ...2 How to Use this Manual 2 Safe Working Load 2 Important Safety Directions 3 Shock Prevention 3 Environmental Advice 3 Homecare Environment Considerations 3 Symbols Used 3 General Symbols 3 Product D...

Страница 4: ...001 04100 EN rev 2 Table of Contents iv...

Страница 5: ...vice or repair the BHMTurntable If any unit is defective contact your local ArjoHuntleigh vendor Always ensure that the BHMTurntable is installed and put into service by an authorized ArjoHuntleigh co...

Страница 6: ...ife span has been exceeded Wear may cause the breakage of a part and lead to a patient fall The life span is the safe operating time period before a complete overhaul is required Following are factors...

Страница 7: ...tion herein Always ensure that The unit is used by trained staff All controls and safety features are used only as per the rules specified in this manual Never attempt to force a control on the BHMTur...

Страница 8: ...table Max capacity 272kg 600lb Indoor use only Made in Canada 001 02294 REV 2 2013 05 700 04200 ArjoHuntleigh AB Verkstadsv gen 5 241 38 Esl v SWEDEN XXXXXXXXX 7 SAMPLE Legend 1 Activation Cord 2 Acti...

Страница 9: ...ng the cords 4 Move the lift out of the turntable along the new path 5 In case of a malfunction pull down the activation arm to unlock the pivoting track and rotate the track manually 6 WARNING Take c...

Страница 10: ...d Service Manual Failure to meet these requirements could result in personal injuries and or unsafe equipment POINTS TO BE INSPECTED BY USER SERVICE TECHNICIAN FREQUENCY Annually or 1500 cycles Before...

Страница 11: ...NTAL CONDITIONS Ambient temperature range Operation 10 C to 40 C 14 F to 122 F Storage 40 C to 70 C Relative humidity range Operation 30 to 75 non condensing Storage 10 to 100 non condensing Atmospher...

Страница 12: ...001 04100 EN rev 2 Product Dimensions 8 Product Dimensions Dimensions Fig 3 460 mm 18 1 8 320 mm 12 5 8 100 5 mm 3 15 16 502 5 mm 19 3 4 SQ...

Страница 13: ......

Страница 14: ......

Страница 15: ...UNSTABLE LU5 5XF Tel 44 0 1582 745 800 Fax 44 0 1582 745 866 E mail international ArjoHuntleigh com ITALIA ArjoHuntleigh S p A Via di Tor Vergata 432 IT 00133 ROMA Tel 39 0 6 87426211 Fax 39 0 6 87426...

Страница 16: ...oHuntleigh GETINGE and MAQUET ArjoHuntleigh focuses on patient mobility and wound management solutions GETINGE provides solutions for infection control within healthcare and contamination prevention w...

Отзывы: