Aritech EV100P Series Скачать руководство пользователя страница 1

- 6 -

English

MOUNTING INSTRUCTIONS (fig. 1).

Open detector 

À 

and remove electronics module 

Â

, taking care not to

touch pyroelectric sensor 

Ã

.

Break out one or both cable entry hole(s) as required 

Ä

.

Select mounting holes for corner 

Å

 or flat wall 

Æ

 mounting.

Use the base as a template for marking screw hole locations on the wall.

Fasten the base to the wall.

Strip cable for 5 cm and pull it through the cable entry hole(s) and strain
relief.

Replace the electronics module 

Â

 and wire the sensor as shown (fig. 3).

Move jumpers as required, replace cover 

À

, insert screw

 

Ç

.

The detector should be mounted at a height of 1.8 to 3.0 metres.

SITING THE DETECTOR (fig. 2).
Install the detector so that the expected movement of an intruder will be across
the fields of view. This is the direction best detected by PIR detectors.
Avoid possible false alarm sources such as:
-

Direct sunlight onto the detector.

-

Heat sources in a field of view (heaters, radiators, etc.).

-

Strong air draughts onto the detector (fans, air conditioning etc.).

-

Large animals (dogs, cats) in a field of view.

PROGRAMMING THE SENSITIVITY.
Sensitivity is programmed according to the position of jumper J1.

BI. BI-CURTAIN MODE: In this setting an extra level of processing is applied
to provide enhanced stability in the presence of false alarm hazards in smaller
areas.
Note: 

Bi-curtain is used to reduce the possibility of false alarms. It looks for

signal verification and requires the intruder to be seen in two curtains for an
alarm. Not to be used in undercrawl and long range application.

STD. STANDARD SENSITIVITY: Suitable for most wide-angle applications
and for single curtain pattern.

Programme the range at jumper J2 for range under 7 metres or to 12 metres
for wide angle application. It is important to programme the sensor correctly for
optimum sensitivity. Close the detector 

À

. Walk test the sensor regularly by

walking across the fields of view and checking that the LED lights and that the
opening relay is indicated back at the control panel.

LED JUMPER AND REMOTE CONTROL OF LED.
(EV125P/EV126P).
Move jumper J3 to position OFF/REMOTE. The LED is now disabled. It may be
enabled by moving the jumper J3 to the ON position or remotely by applying a
0 V potential to terminal 8.

ALARM MEMORY.
(EV135P/EV136P).
Note: 
First set the Control Voltage ("CV") by jumper J4 (fig. 3b & 4b).
(For example: J4 = "-", then "CV" = 0 Volt = "Low").

Connect "CV" to terminal 9 when the system is armed. When system is
disarmed, disconnect the "CV". If an alarm has occured during the armed
period, the detector or detectors which gave the alarm are indicated by a
flashing LED. Re-applying the "CV" (re-arming the system) will reset LED
indication and memory.

REMOTE ENABLE/DISABLE OF WALK TEST LED.
To walk test the detector, the "CV" to terminal 9 (latch) must be disconnected.
Connect "CV" to terminal 10. The detector’s LED will now light and go out again
as the alarm relay opens and closes, making possible walk testing.

Note 1: Enabling the walk test will not clear alarm memory. After disarming the
system after an alarm, you may switch to walk test. When you switch back out
of walk test, the indication of memorized alarms will re-appear. Only when "CV"
is re-applied to terminal 9 (ie. system is re-armed) will LEDs and memory be
cleared.

Note 2: To enable the walk test LED without a remote "CV" input, connect a link
between terminal 2 and 10, J4 = "+".

SELECTING THE COVERAGE PATTERNS.
Mask the appropriate mirror curtains with the adhesive labels provided and
reassemble the sensor module.

For example:
See fig. 6 for mirror curtain coverage pattern corresponding to curtain 3A & B,
6A and 7B.

Removing label(s) can damage the mirrorsurface!

WINDOW MASK.
In the presence of objects close to (within 1.5 m) and directly under the detector,
fit the mask to the inside of the window as shown in fig. 8.
This disables the part of the curtains looking at the object, whose closeness
might otherwise destabilize the detector.

"DUALLOOP" APPLICATION (fig. 4).
(EV125P/EV126P).
Programme the unit for "DUALLOOP" application with J5.

J5 not mounted: is standard connection (fig. 3).
J5 mounted: is "DUALLOOP" application (fig. 4; do not wire connector 4  &  7!).

Содержание EV100P Series

Страница 1: ...ening relay is indicated back at the control panel LED JUMPER AND REMOTE CONTROL OF LED EV125P EV126P Move jumper J3 to position OFF REMOTE The LED is now disabled It may be enabled by moving the jumper J3 to the ON position or remotely by applying a 0 V potential to terminal 8 ALARM MEMORY EV135P EV136P Note First set the Control Voltage CV by jumper J4 fig 3b 4b For example J4 then CV 0 Volt Low...

Страница 2: ...t les zones de détection et en vérifiant que la LED s allume CONTRÔLE À DISTANCE DE LA LED EV125P EV126P Placez le cavalier J3 en position OFF REMOTE La LED peut être mise en marche en connectant 0V à la borne 8 MÉMOIRE D ALARME EV135P EV136P Remarque Sélection d abord la polarité de contrôle CV avec le cavalier J4 fig 3b 4b Par exemple J4 alors CV 0 V Negatif Quand le système est armé connecter l...

Страница 3: ...p juistheid IN EN UITSCHAKELEN LED VAN OP AFSTAND EV125P EV126P Plaats jumper J3 in positie OFF REMOTE De LED kan nu van op afstand ingeschakeld worden door 0V op klem 8 aan te sluiten ALARMGEHEUGEN EV135P EV136P Let op Allereerst dient de polariteitsaansturing CV van het alarmgeheugen via jumper J4 ingesteld te worden fig 3b 4b Bijvoorbeeld J4 dan CV 0 Volt Low Sluit CV aan op aansluitklem 9 van ...

Страница 4: ...a a 1 EV100P SERIES PIR DETECTOR fig 1c fig 2 fig 1a fig 1b b b fig 3 fig 4 4 7 open c ...

Страница 5: ...rteKörper geschwindigkeiten Alarmausgang Alarmzeit Sabotageausgang Umgebungstemperatur Rel Luftfeuchtigkeit Abmessungen Gewicht Anzahl Zonen Erfassungswinkel Detectionsweite Gehäusenach mitversiegelter Kabeleinführung Technische gegevens Aansluitspanning Max rimpelspanning Stroomverbruik Normalewerking Alarm Montagehoogte Bewegingssnelheid Alarmuitgang Alarm tijd Sabotageuitgang Temperatuur Relati...

Страница 6: ...Position OFF REMOTE Die LED wird durch Anschaltung von 0V an Klemme 8 aktiviert ALARMSPEICHER EV135P EV136P BEACHTE Zuerst die Polarität zur Ansteuerung CV des Alarmspeichers mit der Steckbrücke J4 einstellen Abb 3b 4b Beispiel J4 dann CV 0 Volt Low Beschalten Sie im scharfen Zustand CV an die Melderklemmen 9 Entfernen Sie die CV beim Unscharfschalten Sollte ein Alarm während des Scharf betriebs a...

Страница 7: ...osi che il LED di allarme si illumini e che l allarme venga indicato sulla centrale di controllo CONTROLLO A DISTANZA DEL LED EV125P EV126P Posizione il ponticello J3 su OFF REMOTE Per attivare l indicatore LED collegare 0 V al morsetto 8 Per l omologazione IMQ e necessario l utilizzo del kit antirimozione ST400 MEMORIA DI ALLARME EV135P EV136P Nota Primaimpostarelatensionedicontrollo CV permezzod...

Страница 8: ...OTO DEL LED EV125P EV126P Situar el puente J3 en al la posición OFF REMOTE El LED puede ahoraser habilitado remotamente aplicando aplicando 0 V en el terminal 8 MEMORIA DE ALARMA EV135P EV136P Nota En pirmer lugar elegir la tensión de control CV con el interruptor J4 fig 3b 4b Por ejemplo el interruptor J4 entonces CV 0 Tensión Baja Conecte CV al terminal 9 del detector cuando el sistema està acti...

Отзывы: