![Aritech ADVISOR CD 3403 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/aritech/advisor-cd-3403/advisor-cd-3403_user-manual_2972107012.webp)
Page 12
User Manual for CD3403
U
PLOADING AND DOWNLOADING IN THE
CD34
The CD34 has the option of controlling, modifying and programming the alarm system remotely by the
installer. With the use of a modem messages can be sent from the control panel to a personal computer
(PC), called uploading, and from a PC to the control panel, called down loading. Uploading and downloading
is therefore a quick and handy aid to easily discovering and solving problems.
A connection can be established in the following ways:
1. The installer dials in to your alarm system. The dialler will then accept and check whether the
connection can be established. The dialler hangs up and then calls the installer back. This
ensures that nobody other that the installer can gain access. When the connection has been
established
‘OK’
appears in the display.
2. By entering a up/down (U/D) load code. This is a code which you can enter when the display is
showing the time and date. If the code is correct, ‘
OK’
appears in the display and the dialler then
calls your installer and establishes a connection.
When the connection has been established ‘
U/D in Progress
’ appears in the display. You can no longer
control your system from that moment until the time and date reappear in the display.