GB
6
Table 1 Liquid Gas Natural Gas
Burner Diameter Thermal Thermal By-pass Nozzle Flow* Thermal Nozzle Flow*
power power 1/100 1/100 (g/h) power 1/100 (l/h)
kW kW kW
(p.c.s.*) (p.c.s.*) (p.c.s.*)
(mm) Reduced Nominal (mm) (mm) *** ** Nominal (mm)
Supply pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
Reduced Fast (RR)
Semi Fast (S)
Auxiliary (A)
Semi-Fishburner (SP)
Double Flame
(DCDR Internal) (2)
Double Flame
(DCDR External)
2 nozzle (2)
100
75
55
—
30
130
0.70
0.40
0.40
0.70
0.40
1.50
2.60
1.65
1.00
1.50
0.90
4.10
39
28
28
39
28
61
80
64
50
60
44
70x2
189
120
73
109
65
298
186
118
71
107
64
293
2.60
1.65
1.00
1.50
0.90
4.10
122 (H)
96 (Y)
79 (6)
88
70
114x2
248
157
95
143
86
390
Double flame
(DCDR internal) (1)
30
0,30
0,90
27
44
65
64
0,90
69
86
Double
flame (1)
(DCDR
internal)
(DCDR
external
2 nozzle)
130
1,50
4,60
27
44
334
329
5,00
69
476
55
70 x 2
113 x 2
Burner and nozzle specifications (for 75 cm versions only)
(1) For single-control DRDA (DCDR) burner only
(2) For dual-control DRDA (DCDR) burner only
*
At 15°C and 1013 mbar - dry gas
**
Propane P.C.S. = 50.37 MJ/Kg
***
Butane P.C.S. = 49.47 MJ/Kg
Natural P.C.S. = 37.78 MJ/m³
PK741RQO GH AG
DC
S
A
PK750RL GH AG
RR
DC
S
S
A
PK760RF GH AG
RR
DC
SP
A
Содержание PK 640 RL GH AG