12
Set Temperature
-
55°C
Min. Settable Temp.
P2
50°C
Max Settable Temp.
(with heat pump only)
P3
55°C
Mode - Auto
-
On - Enabled
Mode - Boost
-
On - Enabled
Mode - Green
P4
Off - Disabled
Mode - Voyage
P6
Off - Disabled
Mode - Programs P1 & P2
P11
Off - Disabled
Programme P1 Temp.
-
55°C
Programme P1 Time
-
06:00hrs
Programme P2 Temp.
-
55°C
Programme P2 Time
-
18:00hrs
Antibacterial Function
P5
Off - Disabled
Defrost
P7
On - Enabled
Time_W
P9
8 hours
3.2
T
URNING
NUOS O
N
3.3
D
EFAULT
S
ETTINGS
Display
Displays set temperature °C, mode, heat pump status and electric heater
status.
Smile Led
ON indicates NUOS is heating water.
Will also flash when system error is displayed, see 8.3.
To turn the NUOS ON and OFF, press the ON/OFF button.
The unit will turn ON in the same mode as when it was turned OFF i.e.
Auto, Boost, Green, Voyage, P1, P2 or P1+P2 (if enabled).
The NUOS has the following default settings on initial power up.
The desired temperature for the hot water is set using the ‘Control knob’ -
refer to 3.1.
The minimum temperature that can be achieved by the heat pump is
between 40°C and 50°C this limit is set by parameter P2.
The maximum temperature that can be achieved by the heat pump without
using the heater element is between 50°C and 55°C this limit is set by
parameter P3.
The maximum temperature that can be achieved using the electric heater
is 65°C.
3.4
S
ETTING
D
ESIRED
T
EMPERATURE
HP
set
AUTO
HP
Heat Pump
active
Electric Heater
active
Set
Temperature
Mode - Auto, Boost, Green, Voyage P1, P2 or P1+P2
If enabled