9
●
We suggest that user shall turn the water flow modulation knob to lower extent in winter and to higher
extent in summer, so as to keep the water temperature in moderate range for your comfortable use.
●If temperature setting cannot be reached because it is beyond range of gas modulation, such case
(is common in winter) shall not be regarded as quality defect. Turn down the water flow to achieve
the set temperature.
4.3 Bathtub water fill-in(only for control panel and wireless remote controller)
4.3.1 Pre-operation preparations
●Close the drainage port in the bathtub.
●Please cover the bathtub lid if mounted. (Open the lid up to let water in)
4.3.2 Please follow the below filling steps if control panel is used.
A. Press the power supply button on the control panel. Then panel flashes to show water fill-in at 42
℃
B. Adjust water fill-in temperature with setting buttons.
Priority indication on
C.
Adjust water volume with setting buttons.
●Tap the water volume setting button. LCD flashes to display water volume setting. Change water flow
volume setting with volume button.
●The water volume range is within 0-990L (unit:10L) according to desire.
●After water fill-in volume be set, LCD flashes to show current setting and fill-in temperature for 8
seconds.
10
D. Open the water-out valve
※
If the mixing valve is used, please turn to hot-water position.
E. Please close the water-out valve when the beeper starts to buzz, the buzz indicates completion
of set volume. By then LCD flashes to show current volume setting for 8 seconds. Please stop filling.
Special note:
The water heater is provided without auto reach-and-stop function.
Default volume setting is 100L.
A. Keep room ventilated
Open the window to ventilate the room during application of water heater.
B. Do not touch the fume exhaust pipe and/or surrounding parts to prevent scald from hot water
when water heater is on or after work.
V. Operation attentions
C. No outdoor use. This water heater is a product designed for indoor only. Don’t make it work outside
because rainwater may penetrate the housing of the water heater and cause damage to it.
Water fill-in
temperature
(e.g. 42
℃
)
Priority indication on
Temperature down
Temperature up
Changed water
fill-in temperature
(e.g. 45
℃
)
Flash to show
water fill-in
volume
(e.g. 100L)
Priority indication on
volume down
volume up