36
Servicing Instructions
1.
Disconnect electrical connections “O” and silicone pipe “P”
(F
IG
.10.25);
2.
Remove screw “Q” and remove the fan collar clamp “R” (F
IG
.
10.26);
3.
Remove screws “S” (F
IG
. 10.27);
4.
Remove fan and mounting plate (F
IG
. 10.28).
10.3.6 Removing the fan
F
IG
. 10.25
O
O
P
F
IG
. 10.26
Q
R
F
IG
. 10.27
S
S
S
F
IG
. 10.28
10.4.1. Removing the spark generator
1.
Disconnect ignition leads “T” by pulling upward
(F
IG
. 10.29);
2.
Remove the screw “U” (F
IG
. 10.30);
3.
Remove the spark generator by pulling forward from the gas
valve (F
IG
. 10.31).
F
IG
. 10.29
F
IG
. 10.30
F
IG
. 10.31
T
U
10.4 Access to the Gas Valve