GB
/ 27
IN CASE THE DEHUMIDIFIER MALFUNCTIONS
BEFORE CONTACTING THE TECHNICAL ASSISTANCE CENTRE, PERFORM THE FOLLOWING CHECKS
PROBLEM
CAUSE
SOLUTION
The appliance does not start by
pressing the ON/OFF button.
1) The plug is not properly inserted.
2) The main switch is not properly inserted.
3) The tank full indicator light is lit.
4) The tank is either full or not properly inserted.
1) Insert the plug correctly.
2) Check the main switch.
3) Empty the tank.
4) Put the tank properly back into place.
The appliance is not able to dehu-
midify the room enough.
1) The air inlet or outlet are obstructed (by cur
-
tains, objects, walls, etc.).
2) The set humidity level is not low enough.
3) The windows and doors of the room are not
closed.
4) The room temperature is either too low (lower
than 5°C) or too high (above 32°C).
5) The air filter is clogged.
1) Free the air inlet and outlet.
2) Appropriately adjust the humidity lev
-
el.
3) Close all windows and doors.
5) Clean the air filter.
The appliance is very noisy.
1) The air filter is clogged.
2) The appliance is inclined.
3) The appliance is resting on a non-flat surface.
1) Clean the air filter.
2) Reposition the appliance.
PRODUCT TECHNICAL SHEET
Type of appliance
Dehumidifier
Supplier brand
ARISTON
Dehumidification
(1)
litres/day
10
12
Power consumption
(1)
(max)
W
230 (
340
)
250 (
350
)
Sound pressure
(1)
dB(A)
46
46
Tipo refrigerante
R290
R290
Type of refrigerant
(2)
3
3
Operating temperature
°C
5/32
5/32
Tank capacity
litres
2.1
2.1
Power supply and no. of phases
Hz - V - Ph
50-230-1
50-230-1
Type of compressor
Reciprocating
Reciprocating
Maximum air flow rate
m3/h
107
118
Standard refrigerant charge
kg /t CO2 eq.
0,045
0,05
Dimensions
mm
360x253x440
360x253x440
Weight (net/gross)
kg
11.4 / 12.1
11.6 / 12.1
(1) Relative to operation at 30°C and 80% relative humidity.
(2) Refrigerant loss contributes to climate change. In case of their release into the atmosphere, refrigerants with lower global warm
-
ing potential (GWP) have less impact on global warming compared to refrigerants with a higher GWP. This appliance contains a
fluorinated greenhouse gas, covered by the Kyoto Protocol, with a GWP of 3. In other words, if 1 kg of this fluorinated greenhouse
gas were released into the atmosphere, the impact on global warming would be 3 times greater compared to 1 kg of CO, over a
period of 100 years. In no case, whatsoever must the user attempt to intervene on the refrigerant circuit or dismantle the product.
In case of need, please contact a qualified professional.