58 / GB
TECHNICAL DATA
Power supply
BUS
Electrical absorption
max. < 0,5W
Operating temperature
-10 ÷ 60°C
Storage temperature
-20 ÷ 70°C
Bus wire length and cross-sectional area
NOTE:
TO AVOID INTERFERENCE PROBLEMS,
USE A SHIELDED CABLE OR TWISTED
PAIR CABLE.
max. 50 m
min. 0.5 mm²
Buffer memory
2 h
Conformity
LVD 2014/35/EU - EMC 2014/30/EU
Electromagnetic interference
EN 60730-1
Electromagnetic emissions
EN 60730-1
Conformity to standards
EN 60730-1
Temperature sensor
NTC 5 k 1%
Resolution degree:
0,1°C
134 mm
16 mm
96 mm
SYSTEM INTERFACE
OUTDOOR SENSOR
Position the outdoor sensor on the north-facing wall of the
building, at least 2.5 m from the ground and away from direct
sunlight.
Remove the cover and install the sensor using the rawl plug
and screw provided. Perform connection using a 2x0.5 mm2
wire.
Maximum connection length 50 m. Connect the wire to the
terminal by introducing it from the lower part after creating a
suitable passage.
Place the sensor cover back in the correct position..
A
B
C
PRODUCT FICHE (valid from September 26th, 2015)
SUPPLIER’S NAME
ARISTON
SUPPLIER’S MODEL IDENTIFIER
SENSYS
OUTDOOR SENSOR
Class of the temperature control
V
II
Contribution to seasonal space heating energy efficiency in %
+3%
+2%
Adding an ARISTON OUTDOOR SENSOR:
Class of the temperature control
VI
--
Contribution to seasonal space heating energy efficiency in %
+4%
--
In a 3-zones system with 2 ARISTON ROOM SENSORS
Class of the temperature control
VIII
--
Contribution to seasonal space heating energy efficiency in %
+5%
--
Содержание 3300831
Страница 24: ...24 IT SCHEMA ELETTRICO QUADRO UNITÀ ESTERNA 1 PH 4kW 5kW 7kW 3 PH 7kW ...
Страница 72: ...72 GB 1 PH 4kW 5kW 7kW 3 PH 7kW ELECTRICAL SCHEME BOX OF EXTERNAL UNIT ...
Страница 98: ...98 GB ...
Страница 99: ...99 GB ...