EN
15
LEGIONELLA BACTERIA FUNCTION
Legionella are small rod shaped bacteria which are a natural constituent of all fresh waters. Legionaries’ disease
is a pneumonia infection caused by inhaling of Legionella species. Long periods of water stagnation should be
avoided; it means the water heater should be used or flushed at least weekly.
The European standard CEN/TR 16355 gives recommendations for good practice concerning the prevention of
Legionella growth in drinking water installations but existing national regulations remain in force.
This electronic storage water heater is sold with a thermal disinfection cycle function enabled by default. Every
time the product is switched on and every 30 days, the thermal disinfection cycle run to heat the water heater
up to 60°C.
Warning
: when this software has been carrying out the thermal disinfection treatment, water temperature can
cause burns. Feel water before bathing or showering.
TECHNICAL CHARACTERISTICS
For the technical specifications, refer to the nameplate (the nameplate is located next to the water intake/outlet
pipes).
Table 1 - Product information
Product range
30
50
80
100
120
Weight (kg)
13
17
22
26
31
Installation
Vertical
Vertical
Vertical
Vertical
Vertical
Model
Refer to the nameplate
SMART
X
X
X
X
X
Qelec (kWh)
3,132
7,445
7,323
7,455
14,324
Qelec, week, smart (kWh)
13,644
28,188
25,435
26,002
56,829
Qelec, week (kWh)
19,358
34,771
32,942
33,778
66,556
Load profile
S
M
M
M
L
L
wa
15 dB
wh
38%
39%
40%
40%
39%
V40 (L)
/
71
92
130
170
Capacity (l)
30
50
80
100
120
The power consumption data in the table and the other information given in the Product Data Sheet (Enclosure
A to this manual) are defined in relation to EU Directives 812/2013 and 814/2013.
The products without the label and the data sheet for water heaters and solar devices, stipulated in regulation
812/2013, are not intended to be used in such assemblies.
The device is equipped with a smart function that allows you to adapt the consumption to the user profiles. If
operated correctly, the device has a daily consumption of “Qelec* (Qelec,week,smart/Qelec,week)” less than that
of an
equivalent product with no smart function”.
This appliance is conforming with the international electrical safety standards IEC 60335-1 and IEC
60335-2-21. The CE marking of the appliances attests its conformity to the following EC Directives, of
which it satisfies the essential requisites:
- LVD Low Voltage Directive: EN 60335-1, EN 60335-2-21, EN 60529, EN 62233, EN 50106.
- EMC Electro-Magnetic Compatibility: EN 55014-1, EN 55014-2, EN 61000-3-2, EN 61000-3-3.
- RoHS2 Risk of Hazardous Substances: EN 50581.
- ErP Energy related Products: EN 50440.
This product is in conformity with REACH regulations.